{"title":"800G QSFP-DD \u0026 OSFP Transceivers","description":null,"products":[{"product_id":"qsfpdd-dr8-800g","title":"800G QSFP-DD DR8 PAM4 800GBASE-DR8 1310nm 500m DOM MTP\/MPO-16 SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFPDD-DR8-800G\u003c\/p\u003e\n\u003cdiv class=\"ctn_box\" data-v-44894fd6=\"\" style=\"display:;\"\u003e \u003cdiv class=\"specification_component\" data-v-44894fd6=\"\" data-v-4e3a3e14=\"\"\u003e \u003cdiv class=\"products_title\" data-v-1e3b6eb2=\"\" data-v-4e3a3e14=\"\"\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e 800G QSFP-DD DR8 800GBASE-DR8 QSFP-DD Optical Transceiver Module (SMF, 1310nm, 500m, MTP\/MPO-16, DOM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv class=\"content\" data-v-1e3b6eb2=\"\"\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e The 800GBASE-DR8 QSFP-DD Optical Transceiver Module is designed for 800GBASE Ethernet throughput up to 500m over singlemode fiber (SMF) with MPO-16 connectors. This transceiver is compliant with IEEE P802.3ck, IEEE 802.3cu, QSFP-DD MSA. The built-in digital diagnostics monitoring (DDM) allows access to real-time operating parameters. It is suitable for 800G Ethernet, Data Center, Breakout 2x 400G DR4 or 8x 100G DR application.\u003c\/p\u003e \u003cdiv class=\"p_con_02 products_note\"\u003e \u003cbr\u003e \u003c\/div\u003e \u003cdiv class=\"wrapper\"\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:476px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePart Number \u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFPDD-DR8-800G\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eVendor Name \u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eForm Factor \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Data Rate \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eWavelength \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1310nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Cable Distance \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMTP\/MPO-16\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMedia \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTransmitter Type \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Type \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eElectric Signal \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e8x100G\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOptical Signal \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e8x100G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDDM\/DOM \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSupported\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eCommercial Temperature Range \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTX Power \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-2.9~4dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Sensitivity \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;-7.9dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePower Consumption \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;16.5W\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eExtinction Ratio \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.5dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eModulation Format \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDSP \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX and RX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTransmitter and Dispersion Eye Closure Quaternary \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e4.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePowerbudget \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1.9dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePackaging Technology \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCOB (chip on board) Packaging\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eFEC Function* \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eNot Supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eProtocols \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cspan class=\"value\" data-v-771bb478=\"\"\u003eIEEE 802.3cu, IEEE P802.3ck, QSFP-DD MSA HW Rev 6.01, CMIS5.0 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eApplication \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800GBASE Data Center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv class=\"p_con_02\"\u003e Please Note:\u003cbr\u003e * FEC in host is required to be turned on to increase the reliability of transmission.\u003c\/div\u003e \u003cdiv class=\"p_con_02\"\u003e \u003c\/div\u003e \u003chr\u003e \u003cdiv class=\"new-mtp-container\"\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Tree\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv class=\"new-proDetail-treeBx\"\u003e \u003cdiv class=\"new-proDetail-treeCont\"\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Direct Connection for 800GBASE-DR8 QSFP-DD Transceivers\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr\u003e \u003cdiv class=\"p_con_01\"\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Quality Testing Program\u003c\/h3\u003e \u003c\/div\u003e \u003cdiv class=\"news_Resources_containner\"\u003e \u003cdiv class=\"news_alone_container news_Resources_left\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr\u003e \u003cdiv class=\"p_con_01\"\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Quality Certifications\u003c\/h3\u003e \u003c\/div\u003e \u003cdiv class=\"p_con_02 products_note\"\u003e \u003cb\u003ePlease Note\u003c\/b\u003e: Installing a third party transceiver does not void your network equipment warranty. Network equipment manufacturers all have guidelines stating that warranty support on their products will not be affected.\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281393201289,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17559-0.jpg?v=1788571289"},{"product_id":"qsfpdd-2fr4-800g","title":"800G QSFP-DD 2FR4 PAM4 800GBASE-2FR4 1310nm 2km DOM Dual CS SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFPDD-2FR4-800G\u003c\/p\u003e\n\u003cdiv class=\"ctn_box\" data-v-44894fd6=\"\" style=\"display:;\"\u003e \u003cdiv class=\"specification_component\" data-v-44894fd6=\"\" data-v-4e3a3e14=\"\"\u003e \u003cdiv class=\"products_title\" data-v-1e3b6eb2=\"\" data-v-4e3a3e14=\"\"\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e 800G QSFP-DD 2FR4 800GBASE-2FR4 QSFP-DD Optical Transceiver Module (SMF, 1310nm, 2Km, CS, DOM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv class=\"content\" data-v-1e3b6eb2=\"\"\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e The 800GBASE-2FR4 QSFP-DD Optical Transceiver Module is designed for 800GBASE Ethernet throughput up to 2Km over singlemode fiber (SMF) with dual cs connectors. This transceiver is compliant with IEEE P802.3ck, IEEE 802.3cu, QSFP-DD MSA. The built-in digital diagnostics monitoring (DDM) allows access to real-time operating parameters. It is suitable for 800G Ethernet, Data Center, Breakout 2x 400G DR4 or 8x 100G DR application.\u003c\/p\u003e \u003cdiv class=\"p_con_02 products_note\"\u003e \u003cbr\u003e \u003c\/div\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:514px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePart Number \u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFPDD-2FR4-800G\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eVendor Name \u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eForm Factor \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Data Rate \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eWavelength \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1271nm, 1291nm,1311nm,1331nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Cable Distance \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDual CS\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMedia \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTransmitter Type \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Type \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eElectric Signal \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e8x100G\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOptical Signal \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e8x100G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDDM\/DOM \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSupported\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eCommercial Temperature Range \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTX Power \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-3.2~4.4dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Sensitivity \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;-7.9dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePower Consumption \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;18W\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eExtinction Ratio \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.5dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eModulation Format \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDSP \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX and RX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTransmitter and Dispersion Eye Closure Quaternary \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e4.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePowerbudget \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1.9dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePackaging Technology \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCOB (chip on board) Packaging\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eFEC Function* \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eNot Supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eProtocols \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cspan class=\"value\" data-v-771bb478=\"\"\u003eIEEE 802.3cu, IEEE P802.3ck, QSFP-DD MSA HW Rev 6.01, CMIS5.0 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eApplication \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800GBASE Data Center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv class=\"p_con_02\"\u003e Please Note:\u003cbr\u003e * FEC in host is required to be turned on to increase the reliability of transmission.\u003c\/div\u003e \u003cdiv class=\"p_con_02\"\u003e \u003c\/div\u003e \u003chr\u003e \u003cdiv class=\"new-mtp-container\"\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Highlights\u003c\/h2\u003e \u003cdiv class=\"spotlights_ctn\" data-v-3689f50f=\"\"\u003e \u003cdiv class=\"spotlights_item\" data-v-3689f50f=\"\"\u003e \u003c\/div\u003e \u003cdiv class=\"spotlights_item\" data-v-3689f50f=\"\"\u003e \u003cspan data-v-3689f50f=\"\"\u003e\u003cspan data-v-3689f50f=\"\"\u003eConnect New 800G Sites to Legacy 400G Sites via 2x400G Breakout\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv class=\"spotlights_item\" data-v-3689f50f=\"\"\u003e \u003cspan data-v-3689f50f=\"\"\u003e\u003cspan data-v-3689f50f=\"\"\u003eBuilt-in Broadcom 7nm DSP Chip, Max. Power Consumption 16.5W\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv class=\"spotlights_item\" data-v-3689f50f=\"\"\u003e \u003cspan data-v-3689f50f=\"\"\u003e\u003cspan data-v-3689f50f=\"\"\u003eSelf-developed 53G EML Laser Chip to Ensure Production\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv class=\"spotlights_item\" data-v-3689f50f=\"\"\u003e \u003cspan data-v-3689f50f=\"\"\u003e\u003cspan data-v-3689f50f=\"\"\u003eParameter Tests for Superior Performance, Quality, and Reliability\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv class=\"spotlights_item\" data-v-3689f50f=\"\"\u003e \u003cspan data-v-3689f50f=\"\"\u003e\u003cspan data-v-3689f50f=\"\"\u003eHigh-speed Connectivity Compliant to IEEE P802.3ck and IEEE 802.3cu\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv class=\"spotlights_more \" data-v-3689f50f=\"\" data-v-d27e203a=\"\" style=\"\"\u003e \u003cdiv class=\"spotlights_item\" data-v-3689f50f=\"\"\u003e \u003cspan data-v-3689f50f=\"\"\u003e\u003cspan data-v-3689f50f=\"\"\u003eHot Pluggable QSFP-DD MSA Compliant\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv class=\"spotlights_item\" data-v-3689f50f=\"\"\u003e \u003cspan data-v-3689f50f=\"\"\u003e\u003cspan data-v-3689f50f=\"\"\u003eSupport 2x400G or 8x 100G Breakout for Higher Port Density\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv class=\"spotlights_item\" data-v-3689f50f=\"\"\u003e \u003cspan data-v-3689f50f=\"\"\u003e\u003cspan data-v-3689f50f=\"\"\u003e8x106.25G PAM4 Retimed 8x100GAUI-1 C2M Electrical Interface\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e \u003cdiv class=\"spotlights_item\" data-v-3689f50f=\"\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv class=\"new-proDetail-treeBx\"\u003e \u003cdiv class=\"new-proDetail-treeCont\"\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Direct Connection for 800GBASE-2LR4 QSFP-DD Transceivers\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr\u003e \u003cdiv class=\"p_con_01\"\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Quality Testing Program\u003c\/h3\u003e \u003c\/div\u003e \u003cdiv class=\"news_Resources_containner\"\u003e \u003cdiv class=\"news_alone_container news_Resources_left\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr\u003e \u003cdiv class=\"p_con_01\"\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Quality Certifications\u003c\/h3\u003e \u003c\/div\u003e \u003cdiv class=\"p_con_02 products_note\"\u003e \u003cb\u003ePlease Note\u003c\/b\u003e: Installing a third party transceiver does not void your network equipment warranty. Network equipment manufacturers all have guidelines stating that warranty support on their products will not be affected.\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281394675849,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17560-0.jpg?v=1788571315"},{"product_id":"osfp-2fr4-800g","title":"800G OSFP 2FR4 PAM4 800GBASE-2FR4 1310nm 2km DOM Dual LC Duplex SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e OSFP-2FR4-800G\u003c\/p\u003e\n\u003cdiv class=\"ctn_box\" data-v-44894fd6=\"\" style=\"display:;\"\u003e \u003cdiv class=\"specification_component\" data-v-44894fd6=\"\" data-v-4e3a3e14=\"\"\u003e \u003cdiv class=\"products_title\" data-v-1e3b6eb2=\"\" data-v-4e3a3e14=\"\"\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e 800G OSFP 2FR4 800GBASE-2FR4 OSFP Optical Transceiver Module (SMF, 1271nm, 1291nm, 1311nm, 1331nm, 2km, LC, DOM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv class=\"content\" data-v-1e3b6eb2=\"\"\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e The 800GBASE-2FR4 OSFP Optical Transceiver Module is designed for 800GBASE Ethernet throughput up to 2km over single-mode fiber (SMF) with duplex LC connectors. The 800 Gigabit Ethernet signal is carried over four wavelengths at 1271, 1291, 1311, 1331 nm. This transceiver is compliant with IEE802.3ck, IEEE 802.3cu, OSFP MSA. The built-in digital diagnostics monitoring (DDM) allows access to real-time operating parameters. It is suitable for 800G Ethernet, Breakout 2x 400G FR4, Data Center, Cloud Networks.\u003c\/p\u003e \u003cdiv class=\"p_con_02 products_note\"\u003e \u003cbr\u003e \u003c\/div\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:521px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePart Number \u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP-2FR4-800G\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eVendor Name \u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eForm Factor \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Data Rate \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eWavelength \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1271\/1291\/1311\/1331nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Cable Distance \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDual LC Duplex\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMedia \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTransmitter Type \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Type \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eElectric Signal \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e8x100G\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOptical Signal \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e8x100G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDDM\/DOM \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSupported\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eCommercial Temperature Range \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTX Power \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-3.2~4.4dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Sensitivity \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;-7.9dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePower Consumption \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;18W\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eExtinction Ratio \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.5dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eModulation Format \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDSP \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX and RX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTransmitter and Dispersion Eye Closure Quaternary \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e4.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePowerbudget \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1.9dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePackaging Technology \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCOB (chip on board) Packaging\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eFEC Function* \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eNot Supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eProtocols \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cspan class=\"value\" data-v-771bb478=\"\"\u003eIEEE 802.3cu, IEEE P802.3ck, OSFP MSA HW Rev 6.01, CMIS5.0 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eApplication \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800GBASE Data Center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv class=\"p_con_02\"\u003e Please Note:\u003cbr\u003e * FEC in host is required to be turned on to increase the reliability of transmission.\u003c\/div\u003e \u003cdiv class=\"p_con_02\"\u003e \u003c\/div\u003e \u003chr\u003e \u003cdiv class=\"new-mtp-container\"\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Highlights\u003c\/h2\u003e \u003cdiv class=\"spotlights_ctn\" data-v-3689f50f=\"\"\u003e \u003cdiv class=\"spotlights_item\" data-v-3689f50f=\"\"\u003e \u003c\/div\u003e Built-in Broadcom 7nm DSP Chip, Max. Power Consumption 18W\u003cbr\u003e Self-developed 53G EML Laser Chip to Ensure Production\u003cbr\u003e Parameter Tests for Superior Performance, Quality, and Reliability\u003cbr\u003e High-speed Connectivity Compliant to IEEE 802.3ck and IEEE 802.3cu-2021\u003cbr\u003e Hot Pluggable OSFP MSA Compliant\u003cbr\u003e Support 2x400G Breakout for Higher Port Density\u003cbr\u003e 8x106.25G PAM4 Retimed 2x400GAUI-4 Electrical Interface\u003cbr\u003e For Higher Bandwidth in Hyperscale Data Centers and Cloud Infrastructure \u003cdiv class=\"spotlights_item\" data-v-3689f50f=\"\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv class=\"new-proDetail-treeBx\"\u003e \u003cdiv class=\"new-proDetail-treeCont\"\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Direct Connection for 800GBASE-DR8 QSFP-DD Transceivers\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr\u003e \u003cdiv class=\"p_con_01\"\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Quality Testing Program\u003c\/h3\u003e \u003c\/div\u003e \u003cdiv class=\"news_Resources_containner\"\u003e \u003cdiv class=\"news_alone_container news_Resources_left\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr\u003e \u003cdiv class=\"p_con_01\"\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Quality Certifications\u003c\/h3\u003e \u003c\/div\u003e \u003cdiv class=\"p_con_02 products_note\"\u003e \u003cb\u003ePlease Note\u003c\/b\u003e: Installing a third party transceiver does not void your network equipment warranty. Network equipment manufacturers all have guidelines stating that warranty support on their products will not be affected.\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cbr\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281395495049,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17561-0.jpg?v=1788571341"},{"product_id":"osfp-dr8-800g","title":"800G OSFP DR8 PAM4 800GBASE-DR8 1310nm 500m DOM MTP\/MPO-16 SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e OSFP-DR8-800G\u003c\/p\u003e\n\u003cdiv class=\"ctn_box\" data-v-44894fd6=\"\" style=\"display:;\"\u003e \u003cdiv class=\"specification_component\" data-v-44894fd6=\"\" data-v-4e3a3e14=\"\"\u003e \u003cdiv class=\"products_title\" data-v-1e3b6eb2=\"\" data-v-4e3a3e14=\"\"\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e 800G OSFP DR8 800GBASE-DR8 OSFP Optical Transceiver Module (SMF, 1310nm, 500m, MTP\/MPO-16, DOM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv class=\"content\" data-v-1e3b6eb2=\"\"\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e The 800GBASE-DR8 OSFP Optical Transceiver Module is designed for 800GBASE Ethernet throughput up to 500m over singlemode fiber (SMF) with MPO-16 connectors. This transceiver is compliant with lEEE P802.3ck, IEEE 802.3cu, OSFP MSA. The built-in digital diagnostics monitoring (DDM) allows access to real-time operating parameters. It is suitable for 800G Ethernet, Data Center, Breakout 2x 400G DR4 or 8x 100G DR Application.\u003c\/p\u003e \u003cdiv class=\"p_con_02 products_note\"\u003e \u003cbr\u003e \u003c\/div\u003e \u003cdiv class=\"wrapper\"\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:460px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePart Number \u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP-DR8-800G\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eVendor Name \u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eForm Factor \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Data Rate \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eWavelength \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1310nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Cable Distance \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMTP\/MPO-16\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMedia \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTransmitter Type \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Type \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eElectric Signal \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e8x100G\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOptical Signal \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e8x100G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDDM\/DOM \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSupported\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eCommercial Temperature Range \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTX Power \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-2.9~4.0dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Sensitivity \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;-7.9dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePower Consumption \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;16.5W\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eExtinction Ratio \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.5dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eModulation Format \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDSP \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX and RX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTransmitter and Dispersion Eye Closure Quaternary \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e4.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePowerbudget \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1.9dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003ePackaging Technology \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCOB (chip on board) Packaging\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eFEC Function* \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eNot Supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eProtocols \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cspan class=\"value\" data-v-771bb478=\"\"\u003eIEEE 802.3cu, IEEE P802.3ck, OSFP MSA HW Rev 6.01, CMIS5.0 \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eApplication \u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800GBASE Data Center\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv class=\"p_con_02\"\u003e Please Note:\u003cbr\u003e * FEC in host is required to be turned on to increase the reliability of transmission.\u003c\/div\u003e \u003cdiv class=\"p_con_02\"\u003e \u003c\/div\u003e \u003chr\u003e \u003cdiv class=\"new-mtp-container\"\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Highlights\u003c\/h2\u003e \u003cdiv class=\"spotlights_ctn\" data-v-3689f50f=\"\"\u003e \u003cdiv class=\"spotlights_item\" data-v-3689f50f=\"\"\u003e \u003c\/div\u003e Connect New 800G Sites to Legacy 400G Sites via 2x400G Breakout\u003cbr\u003e Built-in Broadcom 7nm DSP Chip, Max. Power Consumption 16.5W\u003cbr\u003e Self-developed 53G EML Laser Chip to Ensure Production\u003cbr\u003e Parameter Tests for Superior Performance, Quality, and Reliability\u003cbr\u003e High-speed Connectivity Compliant to IEEE P802.3ck and IEEE 802.3cu\u003cbr\u003e Hot Pluggable OSFP MSA Compliant\u003cbr\u003e Support 2x400G or 8x 100G Breakout for Higher Port Density\u003cbr\u003e 8x106.25G PAM4 Retimed 8x100GAUI-1 C2M Electrical Interface\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv class=\"new-proDetail-treeBx\"\u003e \u003cdiv class=\"new-proDetail-treeCont\"\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Direct Connection for 800GBASE-DR8 QSFP-DD Transceivers\u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr\u003e \u003cdiv class=\"p_con_01\"\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Quality Testing Program\u003c\/h3\u003e \u003c\/div\u003e \u003cdiv class=\"news_Resources_containner\"\u003e \u003cdiv class=\"news_alone_container news_Resources_left\"\u003e \u003c\/div\u003e \u003c\/div\u003e \u003chr\u003e \u003cdiv class=\"p_con_01\"\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Quality Certifications\u003c\/h3\u003e \u003c\/div\u003e \u003cdiv class=\"p_con_02 products_note\"\u003e \u003cb\u003ePlease Note\u003c\/b\u003e: Installing a third party transceiver does not void your network equipment warranty. Network equipment manufacturers all have guidelines stating that warranty support on their products will not be affected.\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cbr\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281396248713,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17562-0.jpg?v=1788571367"},{"product_id":"osfp-xd-dr8-fm","title":"OSFP-XD-1.6T-DR8 1.6T OSFP-XD DR8 PAM4 1311nm 2km MPO-16 SMF Fiber Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e OSFP-XD-DR8-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e 1.6T OSFP-XD DR8 PAM4 Optical Transceiver Module (1311nm MTP\/MPO-16 SMF 2km) Fiber Optic Transceiver\u003c\/h2\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h3\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:476px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP-XD-1.6T-DR8\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP-XD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1x1.6T, 2x800G, 4x400G, 8x200G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1311nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2KM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMTP\/MPO-16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP-XD MSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281450512521,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17749-0.jpg?v=1788572980"},{"product_id":"qsfp-dd-800g-sr8-fm","title":"800G SR8 QSFP-DD 850nm 100m OM4 MMF MPO-16 Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP-DD-800G-SR8-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e QSFP-DD-800G-SR8 800G-SR8 QSFP-DD Optical Transceiver Module(850nm 100m OM4 MMF MPO-16 DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:529px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD-800G-SR8\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e60m on OM3\/100m on OM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMTP\/MPO-16(APC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850nm VCSEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-4.6~+4.0dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD MSA, IEEE 802.3bs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281475612809,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17862-0.png?v=1788573842"},{"product_id":"qsfp-dd-800g-fr8-fm","title":"QSFP-DD 8x100G FR PAM4 1310nm 2km DOM MPO-16 SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP-DD-800G-FR8-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e QSFP-DD-800G-FR8 QSFP-DD 8x100G FR Optical Transceiver Module (SMF, 1310nm, 2km, MPO-16, DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch4 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e F-tone QSFP-DD 8x100G FR\/DR8+ transceiver module is designed for 800 Gigabit Ethernet links over 2km of single-mode fiber. The module contains 8 parallel channels at a center wavelength of 1310nm, each operating at 106.25G. The electrical interface of the module complies with the 800GAUI-8 interface defined by IEEE 802.3ck and complies with QSFP-DD MSA.\u003c\/h4\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:513px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD-800G-FR8\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps(8x 106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1310nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eKP4-FEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMTP\/MPO-16\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-3.1~+4.0dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCMIS Rev 5.0, lEEE802.3ck, IEEE 802.3cu, QSFP-DD MSA\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281476038793,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17863-0.jpg?v=1788573852"},{"product_id":"qsfp-dd-800g-fr8d-fm","title":"QSFP-DD 8x100G FR\/DR8+ PAM4 1310nm 2km DOM Dual MPO-12 SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP-DD-800G-FR8D-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e QSFP-DD-800G-FR8D QSFP-DD 8x100G FR\/DR8+ Optical Transceiver Module (SMF, 1310nm, 2km, Dual MPO-12, DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch4 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e F-tone QSFP-DD 8x100G FR\/DR8+ transceiver module is designed for 800 Gigabit Ethernet links over 2km of single-mode fiber. The module contains 8 parallel channels at a center wavelength of 1310nm, each operating at 106.25G. The electrical interface of the module complies with the 800GAUI-8 interface defined by IEEE 802.3ck and complies with QSFP-DD MSA.\u003c\/h4\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:521px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD-800G-FR8D\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps(8x 106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1310nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eKP4-FEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDual MTP\/MPO-12\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVCSEL\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-3.1~+4.0dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCMIS Rev 5.0, lEEE802.3ck, IEEE 802.3cu, QSFP-DD MSA\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281476694153,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17864-0.jpg?v=1788573874"},{"product_id":"qsfp-dd-800g-lr8-fm","title":"QSFP-DD 8x100G LR PAM4 1310nm 10km MPO-16 SMF FEC Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP-DD-800G-LR8-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e QSFP-DD-800G-LR8 QSFP-DD 8x100G LR PAM4 Optical Transceiver Module (1310nm MPO-16 SMF 10km with FEC DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch4 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e F-tone QSFP-DD 8x100G LR transceiver module is designed for 800 Gigabit Ethernet links over 10 km of single-mode fiber. The module incorporates 8 parallel channels on 1310nm center wavelength, operating at 106.25G per channel. The electrical interface of the module complies with the 800GAUI-8 interface defined by IEEE 802.3ck and complies with QSFP-DD MSA.\u003c\/h4\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:513px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD-800G-LR8\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps(8x 106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1310nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e10km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eKP4-FEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMTP\/MPO-16\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-1.9~+4.8dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eˉ-8.2dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD MSA, IEEE 802.3bs\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281477709961,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17865-0.jpg?v=1788573895"},{"product_id":"qsfp-dd-800g-2fr4l-fm","title":"QSFP-DD 2x400G FR4 PAM4 CWDM4 2km DOM Dual duplex LC SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP-DD-800G-2FR4L-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e QSFP-DD-800G-2FR4L 800G QSFP-DD Optical Transceiver Module (1271nm 1291nm 1311nm 1331nm Dual duplex LC SMF 2km with FEC DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch4 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e F-tone QSFP-DD 2x400G FR4 transceiver module is designed for 800 Gigabit Ethernet links over 2 km of single-mode fiber. The module has eight independent electrical input\/output channels, each operating at speeds up to 106.25 Gbps. The transceiver consists of two transmitter\/receiver units, each operating on a set of four wavelengths on the ITU G.694.2 CWDM grid near 1300nm. The module's electrical interface is compliant with the IEEE 802.3ck defined 800GAUI-8 interface and is QSFP-DD MSA compliant.\u003c\/h4\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:528px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD-800G-2FR4L\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps(8x 106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1271nm, 1291nm, 1311nm, 1331nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDual Duplex LC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCWDM EML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-3.2~+4.4dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD MSA, IEEE 802.3bs\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281480364169,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17874-0.jpg?v=1788573982"},{"product_id":"qsfp-dd-800g-2lr4l-fm","title":"QSFP-DD 2x400G LR4 PAM4 CWDM4 10km Dual duplex LC SMF FEC Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP-DD-800G-2LR4L-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e QSFP-DD 2x400G LR4 PAM4 CWDM4 lanes MUX\/DEMUX design 10km Optical Transceiver Module (1271nm 1291nm 1311nm 1331nm Dual duplex LC SMF 10km with FEC DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch4 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e F-tone QSFP-DD 2x400G LR4 transceiver module is designed for 800 Gigabit Ethernet links over 10km single mode fiber. This transceiver consists of two transmitter\/receiver units, with each operating on a set of 4 wavelengths on the ITU G.694.2 CWDM grid near 1300nm. The electrical interface of the module is compliant with the 800GAUI-8 interface as defined by IEEE 802.3ck and compliant with QSFP-DD MSA.\u003c\/h4\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:528px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD-800G-2LR4L\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps(8x 106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1271nm, 1291nm, 1311nm, 1331nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e10km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDual Duplex LC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCWDM EML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-2.7~+5.1dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eˉ-9dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD MSA, IEEE 802.3bs\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281481052297,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17875-0.jpg?v=1788574006"},{"product_id":"qsfp-dd-800g-fr8l-fm","title":"QSFP-DD 800G FR8 PAM4 CWDM8 2km DOM Duplex LC SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP-DD-800G-FR8L-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e QSFP-DD-800G-FR8L QSFP-DD 800G FR8 Optical Transceiver Module (1271nm, 1291nm, 1311nm, 1331nm, 1351nm, 1371nm, 1391nm, 1411nm, SMF, 2km, Duplex LC, DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:521px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD-800G-FR8L\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps(8x 106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1271nm, 1291nm, 1311nm, 1331nm, 1351nm, 1371nm, 1391nm, 1411nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDuplex LC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCWDM EML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-3.3~+3.5dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD MSA, IEEE 802.3bs\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281482330249,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17876-0.jpg?v=1788574030"},{"product_id":"osfp-800g-sr8-fm","title":"OSFP 8x100G SR8 PAM4 850nm MTP\/MPO-16 100m OM4 MMF FEC Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e OSFP-800G-SR8-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e OSFP-800G-SR8 OSFP 8x100G SR8 PAM4 Optical Transceiver Module (850nm MTP\/MPO-16 MMF 100m OM4 with FEC DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch4 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e F-tone OSFP 8x100G SR8 transceiver modules are designed for 800 Gigabit Ethernet links over 60m OM3 or 100m OM4 fiber. The module has 8 independent channels of electrical input\/output, each operating at up to 106.25Gbps. The transceiver consists of two transmitter\/receiver units, each operating at 850nm wavelength. The transmitter path of the module contains a PAM4 re-timer ASIC with two 4-channel modulator drivers and 8 modulated lasers. On the receiver path, it consists of 8 photodiodes and two 4-channel TIAs with a PAM4 re-timer. The electrical interface of the module complies with the 800GAUI-8 interface defined by IEEE 802.3ck and complies with OSFP MSA.\u003c\/h4\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:490px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP-800G-SR8\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps(8x 106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e60m on OM3\/100m on OM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMTP\/MPO-16\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850nm VCSEL\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-4.6~+4.0dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCMIS Rev 5.0, IEEE P802.3ck and IEEE 802.3cu\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281485770889,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17877-0.png?v=1788584232"},{"product_id":"osfp-800g-fr8-fm","title":"OSFP 8x100G FR PAM4 1310nm MPO-16 2km SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e OSFP-800G-FR8-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e OSFP-800G-FR8 OSFP 8x100G FR Optical Transceiver Module (1310nm MPO-16 SMF 2km DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch4 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e F-tone OSFP 8x100G FR transceiver modules are designed for 800 Gigabit Ethernet links over 2km of single-mode fiber. The module has 8 independent channels of electrical input\/output, each operating at up to 106.25Gbps. This transceiver consists of two transmitter\/receiver units, with each operating on a set of wavelengths on the ITU G.694.2 CWDM grid at 1310nm. The module's transmitter path contains a bidirectional PAM4 re-timer ASIC integrating a silicon photonic laser and two 4-channel modulator drivers. On the receiver path, 8 photodiodes and two 4-channel TIA arrays, and PAM4 re-timers are used.\u003c\/h4\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:490px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP-800G-FR8\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps(8x 106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1310nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMTP\/MPO-16\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-3.1~4.0dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eˉ-7.1dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCMIS Rev 5.0, IEEE P802.3ck and IEEE 802.3cu\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281486033033,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17878-0.jpg?v=1788574058"},{"product_id":"osfp-800g-lr8-fm","title":"OSFP 8x100G LR PAM4 1310nm MPO-16 10km SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e OSFP-800G-LR8-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e OSFP-800G-LR8 OSFP 8x100G LR Optical Transceiver Module (1310nm MPO-16 SMF 10km DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch4 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e F-tone OSFP 8x100G LR transceiver modules are designed for 800 Gigabit Ethernet links over 10 km of single-mode fiber. The module has 8 independent channels of electrical input\/output, each operating at up to 106.25Gbps. This transceiver consists of two transmitter\/receiver units, with each operating on a set of wavelengths on the ITU G.694.2 CWDM grid at 1310nm. The module's transmitter path consists of a bidirectional PAM4 re-timer ASIC integrated with a silicon photonic laser and two 4-channel modulator drivers. On the receiver path, 8 photodiodes and two 4-channel TIA arrays are used, along with a PAM4 re-timer.\u003c\/h4\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:490px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP-800G-LR8\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps(8x 106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1310nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e10km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMTP\/MPO-16\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-1.9~+4.8dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eˉ-8.2dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCMIS Rev 5.0, IEEE P802.3ck and IEEE 802.3cu\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281487016073,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17879-0.jpg?v=1788574076"},{"product_id":"osfp-800g-2lr4l-fm","title":"OSFP 2x400G LR4 PAM4 CWDM4 Dual duplex LC 10km SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e OSFP-800G-2LR4L-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e OSFP-800G-2LR4L OSFP 2x400G LR4 Optical Transceiver Module (1310nm Dual duplex LC SMF 10km DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e F-tone OSFP 2x400G LR4 transceiver modules are designed for 800G Gigabit Ethernet links over 10km of single-mode fiber. The module has 8 independent channels of electrical input\/output, each operating at up to 106.25Gbps. This transceiver consists of two transmitter\/receiver units, with each operating on a set of 4 wavelengths on the ITU G.694.2 CWDM grid near 1300nm. The module's transmitter path contains a bidirectional PAM4 re-timer ASIC integrating an 8-channel modulator driver, 8 externally modulated lasers, and two optical multiplexers. On the receiver path, two optical demultiplexers are coupled to eight photodiodes and two 4-channel TIA arrays, as well as a PAM4 re-timer. The electrical interface of the module complies with the 800GAUI-8 interface defined by IEEE 802.3ck and complies with OSFP MSA.\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:506px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP-800G-2LR4L\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps(8x 106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1271nm, 1291nm, 1311nm, 1331nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e10km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDual Duplex LC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCWDM EML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-2.7~+5.1dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCMIS Rev 5.0, IEEE P802.3ck and IEEE 802.3cu\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281487376521,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17880-0.jpg?v=1788574099"},{"product_id":"osfp-800g-fr8l-fm","title":"OSFP 800G FR8 PAM4 CWDM8 Duplex LC 2km SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e OSFP-800G-FR8L-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e OSFP-800G-FR8L OSFP 800G FR8 Optical Transceiver Module (1271nm, 1291nm, 1311nm, 1331nm, 1351nm, 1371nm, 1391nm, 1411nm Duplex LC SMF 2km DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch4 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e F-tone OSFP 800G FR8 optical transceiver is based on its mature and scalable silicon photonics platform for high-capacity short-distance transmission up to 2 km over single-mode fiber. The product complies with IEE802.3ck and OSFP MSA standards and supports CMIS4.0.\u003c\/h4\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:498px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP-800G-FR8L\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850Gbps(8x 106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1271nm, 1291nm, 1311nm, 1331nm, 1351nm, 1371nm, 1391nm, 1411nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDuplex LC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCWDM EML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-3.3~+3.5dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCMIS Rev 5.0, IEEE P802.3ck and IEEE 802.3cu\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281489178761,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17881-0.jpg?v=1788574132"},{"product_id":"qsfp-dd-800g-dr4-fm","title":"800G QSFP-DD800 DR4 (200G per line) 1311nm 500M Dual MPO-12 SMF Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP-DD-800G-DR4-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e QSFP-DD-800G-DR4 800G-DR4 QSFP-DD Optical Transceiver Module (SMF, 1311nmnm, 500m, Dual MPO-12, DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:513px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD-800G-DR4\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e4x200G, 800GbE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1311nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMTP\/MPO-12\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-2.9~+4.0dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eIEEE 802.3cu, IEEE P802.3ck, QSFP-DD MSA HW Rev 6.01, CMIS5.0\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281490194569,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17882-0.png?v=1788574161"},{"product_id":"qsfp-dd-800g-2fr2l-fm","title":"800G QSFP-DD800 2FR2 (200G per line) 2km 1291\/1311nm Dual Duplex LC SMF Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP-DD-800G-2FR2L-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e QSFP-DD-800G-2FR2L 800G QSFP-DD Optical Transceiver Module (SMF, 1291nm, 1311nm, 2km, Dual CS, DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:528px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD-800G-2FR2L\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e4x200G, 2x400GbE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1291nm, 1311nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDual Duplex LC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-3.2~+4.4dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eIEE802.3ck, IEEE 802.3cu, QSFP-DD MSA\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281490489481,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17883-0.webp?v=1788586259"},{"product_id":"osfp-800g-dr4-fm","title":"800G OSFP DR4 (200G per line) PAM4 1311nm MPO-12 500m SMF DDM Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e OSFP-800G-DR4-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e OSFP-800G-DR4 800G OSFP DR4 Optical Transceiver Module (SMF, 1311nm, 500m, MPO-12, DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:490px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP-800G-DR4\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e4x200G, 800GbE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1311nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMTP\/MPO-12\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-5.9~+4.0dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCMIS Rev 5.0, IEEE P802.3ck and IEEE 802.3cu\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281490653321,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17884-0.jpg?v=1788574176"},{"product_id":"osfp-800g-2fr2l-fm","title":"800G OSFP 2FR2 (200G per line) PAM4 1291\/1311nm 2km DOM Duplex LC SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e OSFP-800G-2FR2L-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e OSFP-800G-2FR2L 800G OSFP 2FR2 Optical Transceiver Module (1291nm, 1311nm, 2km, SMF, Duplex LC, DOM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:506px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP-800G-2FR2L\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e4x200G, 2x400GbE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1291nm, 1311nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDuplex LC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCWDM EML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-3.2~+4.4dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCMIS Rev 5.0, IEEE P802.3ck and IEEE 802.3cu\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281491243145,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17885-0.png?v=1788584216"},{"product_id":"osfp-800g-fr4-fm","title":"800G OSFP FR4 (200G per line) PAM4 CWDM Duplex LC 2km SMF Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e OSFP-800G-FR4-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e OSFP-800G-FR4 800G OSFP FR4 Optical Transceiver Module (CWDM Duplex LC SMF 2km DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:490px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone P\/N\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP-800G-FR4\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOSFP\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e4x200G, 800GbE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCWDM\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDuplex LC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-3.1~4.0dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eˉ-7.1dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCMIS Rev 5.0, IEEE P802.3ck and IEEE 802.3cu\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e800G Ethernet, Data Center Interconnect, Infiniband Interconnects\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281491374217,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17886-0.jpg?v=1788574206"},{"product_id":"nvidia-mellanox-mma4z00-ns-compatible-800gbase-2-x-sr4-sr8-osfp-ihs-finned-top-8-x-100g-pam4-850nm-50m-dual-mpo-12-apc-mmf-infiniband-ndr-transceiver-module","title":"NVIDIA\/Mellanox MMA4Z00-NS Compatible 800GBASE 2 x SR4\/SR8 OSFP IHS\/Finned Top 8 x 100G PAM4 850nm 50m Dual MPO-12\/APC MMF InfiniBand NDR Transceiver Module","description":"\u003ch3 class=\"title\"\u003eNVIDIA\/Mellanox MMA4Z00-NS Compatible 800G OSFP SR8 PAM4 InfiniBand NDR Optical Transceiver (2x SR4, MMF, 850nm, 50m, Dual MTP\/MPO-12 APC, DOM, IHS\/Finned Top)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe NVIDIA\/Mellanox InfiniBand MMA4Z00-NS Compatible OSFP IHS\/Finned Top Optical Transceiver is an InfiniBand 800Gb\/s 2x 400Gb\/s Twin-port OSFP, SR8 multimode, parallel, 8-channel transceiver using two, 2-fiber, 4-channel MPO-12\/APC optical connectors at 400Gb\/s each. The parallel multimode, short reach 8-channel (SR8) design uses 100G-PAM4 modulation and has a maximum fiber reach of 50-meters using 8 multimode fibers. It is qualified for use in InfiniBand NDR end-to-end systems.\u003cbr\u003eDesigned for NVIDIA Quantum-2 InfiniBand networks, this OSFP transceiver delivers 800G high-speed connectivity for leaf-spine architectures and interconnects with NVIDIA ConnectX and BlueField-3 platforms. Its scalable, low-latency optical connectivity makes it well suited for large-scale GPU clusters, AI fabrics, and H100\/H200-based AI deployments.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eNote: \"Finned-top\" transceivers are now called \"Integrated HeatSink\" (IHS) as the cooling fins are integrated into the OSFP connector metal top. Commonly used in air-cooled switches. \"Flat-top\" transceivers are now called \"Riding Heat Sink\" (RHS) as the cooling fins ride on top of the network card or systems internal cages. This is used for both air-cooled and liquid-cooled applications for DGX, ConnectX-7, and BlueField-3 DPUS.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin: 10px 0; line-height: 1.8;\"\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eMMA4Z00-NS\u003c\/td\u003e\n\u003ctd\u003eVendor Name\u003c\/td\u003e\n\u003ctd\u003eF-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eNVIDIA\/Mellanox InfiniBand\u003c\/td\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eDual-port OSFP IHS\/Fins top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd\u003e850Gbps (8×106.25Gbps)\u003c\/td\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Cable Distance\u003c\/td\u003e\n\u003ctd\u003e30m@OM3 \/ 50m@OM4\u003c\/td\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eDual MTP\/MPO-12 APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eMMF\u003c\/td\u003e\n\u003ctd\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd\u003eVCSEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Type\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003ctd\u003eTX Power\u003c\/td\u003e\n\u003ctd\u003e-4.6~-4dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Receiver Power\u003c\/td\u003e\n\u003ctd\u003e-6.4dBm\u003c\/td\u003e\n\u003ctd\u003ePower Budget\u003c\/td\u003e\n\u003ctd\u003e1.8dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Overload\u003c\/td\u003e\n\u003ctd\u003e4dBm\u003c\/td\u003e\n\u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd\u003e16W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtinction Ratio\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;2.5dB\u003c\/td\u003e\n\u003ctd\u003eDDM\/DOM\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70℃ (32 to 158℉)\u003c\/td\u003e\n\u003ctd\u003eModulation (Electrical)\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation (Optical)\u003c\/td\u003e\n\u003ctd\u003eDual 4×100G-PAM4\u003c\/td\u003e\n\u003ctd\u003eCDR (Clock and Data Recovery)\u003c\/td\u003e\n\u003ctd\u003eTX \u0026amp; RX Built-in CDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFEC Function\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e6720167 hrs (40℃, 60% Conf.) \/ 4277043 hrs (40℃, 90% Conf.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, CMIS 5.0, IEEE 802.3db, IEEE 802.3ck\u003c\/td\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003e800G Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48312241062025,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/MMA4Z00-NS.jpg?v=1789004055"},{"product_id":"nvidia-mellanox-mma4z00-ns-flt-compatible-800gbase-2-x-sr4-sr8-osfp-rhs-flat-top-8-x-100g-pam4-850nm-50m-dual-mpo-12-apc-mmf-infiniband-ndr-transceiver-module","title":"NVIDIA\/Mellanox MMA4Z00-NS-FLT Compatible 800GBASE 2 x SR4\/SR8 OSFP RHS\/Flat Top 8 x 100G PAM4 850nm 50m Dual MPO-12\/APC MMF InfiniBand NDR Transceiver Module","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eNVIDIA\/Mellanox MMA4Z00-NS-FLT Compatible 800GBASE-SR8 OSFP PAM4 InfiniBand NDR Optical Transceiver Module (MMF, 850nm, 50m, Dual MTP\/MPO-12\/APC, DOM, RHS\/Flat Top)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe NVIDIA\/Mellanox InfiniBand MMA4Z00-NS-FLT compatible OSFP RHS\/Flat Top optical transceiver delivers InfiniBand NDR 800Gb\/s connectivity with dual 400Gb\/s ports, 8-channel SR8 multimode transmission, and dual MPO-12\/APC connectors. The SR8 transceiver uses 100G-PAM4 modulation, supports up to 50m reach over 8 multimode fibers, and is qualified for InfiniBand NDR end-to-end systems.\u003cbr\u003eDesigned for NVIDIA B200\/H200\/H100 InfiniBand architectures, the RHS\/Flat Top version enables high-speed connectivity with Cedar-7 systems with dual ConnectX-7 adapters, delivering reliable interconnects for supercomputing and HPC applications.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eNote: \"Finned-top\" transceivers are now called \"Integrated Heat Sink\" (IHS), designed for air-cooled switches. \"Flat-top\" transceivers are now called \"Riding Heat Sink\" (RHS), supporting both air- and liquid-cooled applications with heat sinks mounted on system cages or network cards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eMMA4Z00-NS-FLT\u003c\/td\u003e\n\u003ctd\u003eVendor Name\u003c\/td\u003e\n\u003ctd\u003eF-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eNVIDIA\/Mellanox InfiniBand Compatible\u003c\/td\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTwin-port OSFP RHS\/Flat Top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd\u003e850Gbps (8×106.25Gbps)\u003c\/td\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Distance\u003c\/td\u003e\n\u003ctd\u003e30m@OM3 \/ 50m@OM4\u0026amp;OM5\u003c\/td\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eDual MTP\/MPO-12 APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eMMF\u003c\/td\u003e\n\u003ctd\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd\u003eVCSEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Type\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003ctd\u003eTX Power\u003c\/td\u003e\n\u003ctd\u003e-4.6~4dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Receiver Power\u003c\/td\u003e\n\u003ctd\u003e-6.3dBm\u003c\/td\u003e\n\u003ctd\u003ePower Budget\u003c\/td\u003e\n\u003ctd\u003e1.7dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Overload\u003c\/td\u003e\n\u003ctd\u003e4dBm\u003c\/td\u003e\n\u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd\u003e16W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtinction Ratio\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;2.5dB\u003c\/td\u003e\n\u003ctd\u003eDDM\/DOM\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70℃ (32 to 158°F)\u003c\/td\u003e\n\u003ctd\u003eModulation (Electrical)\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation (Optical)\u003c\/td\u003e\n\u003ctd\u003eDual 4×100G-PAM4\u003c\/td\u003e\n\u003ctd\u003eCDR (Clock and Data Recovery)\u003c\/td\u003e\n\u003ctd\u003eTX \u0026amp; RX Built-in CDR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInbuilt FEC\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3-2022, IEEE 802.3ck-2022, CMIS Rev 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years①\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48312411127945,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/MMA4Z00-NS-FLT.jpg?v=1789004942"},{"product_id":"nvidia-mellanox-compatible-800gbase-sr8-osfp-ihs-closed-finned-top-8-x-100g-pam4-850nm-100m-mpo-16-apc-mmf-infiniband-ndr-transceiver-module","title":"NVIDIA\/Mellanox Compatible 800GBASE-SR8 OSFP IHS\/Closed Finned Top 8 x 100G PAM4 850nm 100m MPO-16\/APC MMF InfiniBand NDR Transceiver Module","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eNVIDIA\/Mellanox Compatible 800G OSFP SR8 PAM4 InfiniBand NDR Optical Transceiver (MMF, 850nm, 100m, MTP\/MPO-16 APC, DOM, IHS\/Closed Finned Top)\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe NVIDIA\/Mellanox InfiniBand Compatible OSFP IHS\/Closed Finned Top Optical Transceiver is an 800Gb\/s InfiniBand OSFP transceiver featuring a single-port 1×800Gb\/s SR8 multimode interface. It uses a single MTP®\/MPO-16 APC connector with 8 parallel optical channels. The SR8 design employs 100G PAM4 modulation and supports transmission distances of up to 100 meters over multimode fiber using 8 fiber pairs (16 fibers). It is qualified for use in end-to-end NVIDIA InfiniBand NDR systems.\u003cbr\u003eDesigned for NVIDIA Quantum-2 InfiniBand networks, this OSFP transceiver delivers 800G high-speed connectivity for leaf-spine architectures and interconnects with NVIDIA ConnectX and BlueField-3 platforms. Its scalable, low-latency optical connectivity makes it well suited for large-scale GPU clusters, AI fabrics, and H100\/H200-based AI deployments.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eNote: \"Finned-top\" transceivers are now called \"Integrated HeatSink\" (IHS) as the cooling fins are integrated into the OSFP connector metal top. Commonly used in air-cooled switches. \"Flat-top\" transceivers are now called \"Riding Heat Sink\" (RHS) as the cooling fins ride on top of the network card or systems internal cages. This is used for both air-cooled and liquid-cooled applications for DGX, ConnectX-7, and BlueField-3 DPUS.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eOSFP-SR8-800G\u003c\/td\u003e\n\u003ctd\u003eVendor Name\u003c\/td\u003e\n\u003ctd\u003eF-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eSingle-port OSFP IHS\/Closed Finned Top\u003c\/td\u003e\n\u003ctd\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd\u003e850Gbps (8×106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003ctd\u003eMax. Cable Distance\u003c\/td\u003e\n\u003ctd\u003e60m@OM3 \/100m@OM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMTP\/MPO-16 APC\u003c\/td\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eMMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd\u003eVCSEL\u003c\/td\u003e\n\u003ctd\u003eReceiver Type\u003c\/td\u003e\n\u003ctd\u003ePD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX Power\u003c\/td\u003e\n\u003ctd\u003e-4.6~4dBm\u003c\/td\u003e\n\u003ctd\u003eMinimum Receiver Power\u003c\/td\u003e\n\u003ctd\u003e-6.4dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Budget\u003c\/td\u003e\n\u003ctd\u003e1.8dB\u003c\/td\u003e\n\u003ctd\u003eReceiver Overload\u003c\/td\u003e\n\u003ctd\u003e4dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd\u003e16W\u003c\/td\u003e\n\u003ctd\u003eExtinction Ratio\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;2.5dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDDM\/DOM\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003ctd\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70℃ (32 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation (Electrical)\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003ctd\u003eModulation (Optical)\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCDR (Clock and Data Recovery)\u003c\/td\u003e\n\u003ctd\u003eTX \u0026amp; RX Built-in CDR\u003c\/td\u003e\n\u003ctd\u003eInbuilt FEC\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA Rev 5.1, CMIS Rev 5.0, IEEE 802.3df-2024, IEEE 802.3dj-2024\u003c\/td\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48312631918729,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/OSFP-SR8-800G.jpg?v=1789005987"},{"product_id":"nvidia-mellanox-mms4x00-nm-compatible-800gbase-2-x-dr4-dr8-osfp-ihs-closed-finned-top-8-x-100g-pam4-1310nm-500m-dual-mpo-12-apc-smf-infiniband-ndr-transceiver-module","title":"NVIDIA\/Mellanox MMS4X00-NM Compatible 800GBASE 2 x DR4\/DR8 OSFP IHS\/Closed Finned Top 8 x 100G PAM4 1310nm 500m Dual MPO-12\/APC SMF InfiniBand NDR Transceiver Module","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eNVIDIA\/Mellanox MMS4X00-NM Compatible 800G OSFP DR8 PAM4 InfiniBand NDR Optical Transceiver (2x DR4, SMF, 1310nm, 500m, Dual MTP\/MPO-12 APC, DOM, IHS\/Closed Finned Top)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe NVIDIA\/Mellanox InfiniBand MMS4X00-NM Compatible OSFP IHS\/Closed Finned Top Optical Transceiver is an InfiniBand 800Gb\/s 2x 400Gb\/s Twin-port OSFP, DR8 single mode, parallel, 8-channel transceiver using two, 2-fiber, 4-channel MPO-12\/APC optical connectors at 400Gb\/s each. The parallel single mode, reach 8-channel (DR8) design uses 100G-PAM4 modulation and has a maximum fiber reach of 500-meters using 8 single mode fibers. It is qualified for use in InfiniBand NDR end-to-end systems.\u003cbr\u003eThe twin-port OSFP IHS\/Closed Finned Top transceiver is used in Quantum-2 air-cooled switches. Featured with low latency, low power, and reliability, it can link upward in spine-leaf architectures for switch-to-switch applications, downward for top-of-rack switch links to ConnectX® smart network adapters, and\/or to BlueField-3 DPUs in compute servers and storage subsystems. It is the ideal solution for HPC computing, AI, and cloud data centers.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eNote: \"Finned-top\" transceivers are now called \"Integrated HeatSink\" (IHS) as the cooling fins are integrated into the OSFP connector metal top. Commonly used in air-cooled switches. \"Flat-top\" transceivers are now called \"Riding Heat Sink\" (RHS) as the cooling fins ride on top of the network card or systems internal cages. This is used for both air-cooled and liquid-cooled applications for DGX, ConnectX-7, and BlueField-3 DPUS.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eMMS4X00-NM\u003c\/td\u003e\n\u003ctd\u003eVendor Name\u003c\/td\u003e\n\u003ctd\u003eF-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eNVIDIA\/Mellanox InfiniBand Compatible\u003c\/td\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTwin-port OSFP IHS\/Closed Finned Top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd\u003e850Gbps (8×106.25Gbps)\u003c\/td\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Distance\u003c\/td\u003e\n\u003ctd\u003e500m\u003c\/td\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eDual MTP\/MPO-12 APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eSMF\u003c\/td\u003e\n\u003ctd\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd\u003eEML\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Type\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003ctd\u003eTX Power\u003c\/td\u003e\n\u003ctd\u003e-2.9~4.0dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Receiver Power\u003c\/td\u003e\n\u003ctd\u003e-5.9dBm\u003c\/td\u003e\n\u003ctd\u003ePower Budget\u003c\/td\u003e\n\u003ctd\u003e3dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Overload\u003c\/td\u003e\n\u003ctd\u003e4dBm\u003c\/td\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e16.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtinction Ratio\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;3.5dB\u003c\/td\u003e\n\u003ctd\u003eModulation (Electrical)\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation (Optical)\u003c\/td\u003e\n\u003ctd\u003eDual 4×100G-PAM4\u003c\/td\u003e\n\u003ctd\u003ePackaging Technology\u003c\/td\u003e\n\u003ctd\u003eCOB (Chip on Board) Packaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation Format\u003c\/td\u003e\n\u003ctd\u003ePAM4\u003c\/td\u003e\n\u003ctd\u003eCDR (Clock and Data Recovery)\u003c\/td\u003e\n\u003ctd\u003eTX \u0026amp; RX Built-in DSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInbuilt FEC\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA HW Rev 4.1, CMIS Rev 5.0, IEEE 802.3cu-2021, IEEE P802.3ck D2.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48312792711305,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/MMS4X00-NM.jpg?v=1789006666"},{"product_id":"nvidia-mellanox-mms4x00-ns-compatible-800gbase-2-x-dr4-dr8-osfp-ihs-finned-top-8-x-100g-pam4-1310nm-100m-dual-mpo-12-apc-smf-infiniband-ndr-transceiver-module","title":"NVIDIA\/Mellanox MMS4X00-NS Compatible 800GBASE 2 x DR4\/DR8 OSFP IHS\/Finned Top 8 x 100G PAM4 1310nm 100m Dual MPO-12\/APC SMF InfiniBand NDR Transceiver Module","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eNVIDIA\/Mellanox MMS4X00-NS Compatible 800G OSFP DR8L PAM4 InfiniBand NDR Optical Transceiver (2x DR4, SMF, 1310nm, 100m, Dual MTP\/MPO-12 APC, DOM, IHS\/Finned Top)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe NVIDIA\/Mellanox InfiniBand MMS4X00-NS Compatible OSFP IHS\/Finned Top Optical Transceiver is an InfiniBand 800Gb\/s 2x 400Gb\/s Twin-port OSFP, DR8L single mode, parallel, 8-channel transceiver using two, 2-fiber, 4-channel MPO-12\/APC optical connectors at 400Gb\/s each. The parallel single mode, reach 8-channel (DR8L) design uses 100G-PAM4 modulation and has a maximum fiber reach of 100-meters using 8 single mode fibers. It is qualified for use in InfiniBand NDR end-to-end systems.\u003cbr\u003eThe twin-port OSFP IHS\/finned top transceiver is used in Quantum-2 air-cooled switches. Featured with low latency, low power, and reliability, it can link upward in spine-leaf architectures for switch-to-switch applications, downward for top-of-rack switch links to ConnectX® smart network adapters, and\/or to BlueField-3 DPUs in compute servers and storage subsystems. It is the ideal solution for HPC computing, AI, and cloud data centers.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eNote: \"Finned-top\" transceivers are now called \"Integrated HeatSink\" (IHS) as the cooling fins are integrated into the OSFP connector metal top. Commonly used in air-cooled switches. \"Flat-top\" transceivers are now called \"Riding Heat Sink\" (RHS) as the cooling fins ride on top of the network card or systems internal cages. This is used for both air-cooled and liquid-cooled applications for DGX, ConnectX-7, and BlueField-3 DPUS.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eMMS4X00-NS\u003c\/td\u003e\n\u003ctd\u003eVendor Name\u003c\/td\u003e\n\u003ctd\u003eF-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eNVIDIA\/Mellanox InfiniBand Compatible\u003c\/td\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTwin-port OSFP IHS\/Finned Top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd\u003e850Gbps (8×106.25Gbps)\u003c\/td\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e1310nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Distance\u003c\/td\u003e\n\u003ctd\u003e100m\u003c\/td\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eDual MTP\/MPO-12 APC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eSMF\u003c\/td\u003e\n\u003ctd\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd\u003eEML\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Type\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003ctd\u003eTX Power\u003c\/td\u003e\n\u003ctd\u003e-2.9~4.0dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Receiver Power\u003c\/td\u003e\n\u003ctd\u003e-5.9dBm\u003c\/td\u003e\n\u003ctd\u003ePower Budget\u003c\/td\u003e\n\u003ctd\u003e3dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Overload\u003c\/td\u003e\n\u003ctd\u003e4dBm\u003c\/td\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e17W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtinction Ratio\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;3.5dB\u003c\/td\u003e\n\u003ctd\u003eModulation (Electrical)\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation (Optical)\u003c\/td\u003e\n\u003ctd\u003eDual 4×100G-PAM4\u003c\/td\u003e\n\u003ctd\u003ePackaging Technology\u003c\/td\u003e\n\u003ctd\u003eCOB (Chip on Board) Packaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation Format\u003c\/td\u003e\n\u003ctd\u003ePAM4\u003c\/td\u003e\n\u003ctd\u003eCDR (Clock and Data Recovery)\u003c\/td\u003e\n\u003ctd\u003eTX \u0026amp; RX Built-in DSP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInbuilt FEC\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3cu-2021, IEEE P802.3ck D2.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Yearsⓘ\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48316687024265,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/MMS4X00-NS.jpg?v=1789020166"},{"product_id":"nvidia-mellanox-mms4x50-nm-compatible-800gbase-2-x-fr4-osfp-ihs-closed-finned-top-8-x-100g-pam4-1310nm-2km-dual-duplex-lc-upc-smf-infiniband-ndr-transceiver-module","title":"NVIDIA\/Mellanox MMS4X50-NM Compatible 800GBASE 2 x FR4 OSFP IHS\/Closed Finned Top 8 x 100G PAM4 1310nm 2km Dual Duplex LC\/UPC SMF InfiniBand NDR Transceiver Module","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eNVIDIA\/Mellanox MMS4X50-NM Compatible 800G OSFP 2x FR4 PAM4 InfiniBand NDR Optical Transceiver (SMF, 1271nm, 1291nm, 1311nm and 1331nm, 2km, Dual Duplex LC\/UPC, DOM, Closed Finned Top)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe NVIDIA\/Mellanox InfiniBand MMS4X50-NM Compatible OSFP IHS\/Closed Finned Top Optical Transceiver is an 800Gb\/s 2x 400Gb\/s Twin-port OSFP, 2x FR4 single mode, Multiplexed, 8-channel transceiver using two, 2-fiber, LC Duplex optical connectors each carrying 4-channels of 100G-PAM4. The dual Far Reach 8-channel (2x FR4) design uses 100G-PAM4 electrical and optical modulation based on the CWDM4 serial, multiplexed 1310nm wavelength grid. It is qualified for use in InfiniBand NDR end-to-end systems.\u003cbr\u003eThe twin-port OSFP IHS\/Closed Finned Top transceiver is used in Quantum-2 air-cooled switches. Featured with low latency, low power, and reliability, it can link upward in spine-leaf architectures for switch-to-switch applications, downward for top-of-rack switch links to ConnectX® smart network adapters, and\/or to BlueField-3 DPUs in compute servers and storage subsystems. It is the ideal solution for HPC computing, AI, and cloud data centers.\u003c\/p\u003e\n\u003cp\u003eNote: \"Finned-top\" transceivers are now called \"Integrated HeatSink\" (IHS) as the cooling fins are integrated into the OSFP connector metal top. Commonly used in air-cooled switches. \"Flat-top\" transceivers are now called \"Riding Heat Sink\" (RHS) as the cooling fins ride on top of the network card or systems internal cages. This is used for both air-cooled and liquid-cooled applications for DGX, ConnectX-7, and BlueField-3 DPUS.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eMMS4X50-NM\u003c\/td\u003e\n\u003ctd\u003eVendor Name\u003c\/td\u003e\n\u003ctd\u003eF-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eNVIDIA\/Mellanox InfiniBand Compatible\u003c\/td\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTwin-port OSFP IHS\/Closed Finned Top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd\u003e850Gbps (8×106.25Gbps)\u003c\/td\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e1271nm, 1291nm, 1311nm and 1331nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Distance\u003c\/td\u003e\n\u003ctd\u003e2km\u003c\/td\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eDual Duplex LC\/UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eSMF\u003c\/td\u003e\n\u003ctd\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd\u003eEML\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Type\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003ctd\u003eTX Power\u003c\/td\u003e\n\u003ctd\u003e-3.2~4.4dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Receiver Power\u003c\/td\u003e\n\u003ctd\u003e-7.2dBm\u003c\/td\u003e\n\u003ctd\u003ePower Budget\u003c\/td\u003e\n\u003ctd\u003e4dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Overload\u003c\/td\u003e\n\u003ctd\u003e4.4dBm\u003c\/td\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e16.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtinction Ratio\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;3.5dB\u003c\/td\u003e\n\u003ctd\u003eDDM\/DOM\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003ctd\u003eModulation (Electrical)\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation (Optical)\u003c\/td\u003e\n\u003ctd\u003eDual 4×100G-PAM4\u003c\/td\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA HW Rev 4.1, CMIS Rev 5.0, IEEE 802.3cu-2021, IEEE P802.3ck D2.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48316830023817,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/MMS4X50-NM.jpg?v=1789021400"},{"product_id":"nvidia-mellanox-compatible-800gbase-2-x-xdr4-xdr8-osfp-ihs-closed-finned-top-8-x-100g-pam4-1310nm-2km-dual-mpo-12-apc-smf-infiniband-ndr-transceiver-module","title":"NVIDIA\/Mellanox Compatible 800GBASE 2 x XDR4\/XDR8 OSFP IHS\/Closed Finned Top 8 x 100G PAM4 1310nm 2km Dual MPO-12\/APC SMF InfiniBand NDR Transceiver Module","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eNVIDIA\/Mellanox Compatible 800G OSFP XDR8 PAM4 InfiniBand NDR Optical Transceiver Module (2x XDR4, SMF, 1310nm, 2km, Dual MTP\/MPO-12\/APC, DOM, IHS\/Closed Finned Top)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe NVIDIA\/Mellanox InfiniBand Compatible OSFP IHS\/Closed Finned Top Optical Transceiver is an InfiniBand 800Gb\/s 2x 400Gb\/s Twin-port OSFP, XDR8 single-mode, parallel, 8-channel transceiver using two, 2-fiber, 4-channel MPO-12\/APC optical connectors at 400Gb\/s each. The modules uses 100G-PAM4 modulation and has a maximum fiber reach of 2000-meters using 8 single-mode fibers. It is qualified for use in InfiniBand NDR end-to-end systems.\u003cbr\u003eDesigned for NVIDIA Quantum-2 InfiniBand networks, this OSFP transceiver delivers 800G high-speed connectivity for leaf-spine architectures and interconnects with NVIDIA ConnectX and BlueField-3 platforms. Its scalable, low-latency optical connectivity makes it well suited for large-scale GPU clusters, AI fabrics.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eNote: \"Finned-top\" transceivers are now called \"Integrated Heat Sink\" (IHS), designed for air-cooled switches. \"Flat-top\" transceivers are now called \"Riding Heat Sink\" (RHS), supporting both air- and liquid-cooled applications with heat sinks mounted on system cages or network cards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eOSFP800-XDR8-B2\u003c\/td\u003e\n\u003ctd\u003eVendor Name\u003c\/td\u003e\n\u003ctd\u003eF-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eTwin-port OSFP IHS\/Closed Finned Top\u003c\/td\u003e\n\u003ctd\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd\u003e850Gbps (8×106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e1310nm\u003c\/td\u003e\n\u003ctd\u003eMax Cable Distance\u003c\/td\u003e\n\u003ctd\u003e2km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eDual MPO-12\/APC\u003c\/td\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eSMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd\u003eEML\u003c\/td\u003e\n\u003ctd\u003eReceiver Type\u003c\/td\u003e\n\u003ctd\u003eSiphotonics PIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX Power\u003c\/td\u003e\n\u003ctd\u003e-3.1~4dBm\u003c\/td\u003e\n\u003ctd\u003eMinimum Receiver Power\u003c\/td\u003e\n\u003ctd\u003e-7.1dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Budget\u003c\/td\u003e\n\u003ctd\u003e4dB\u003c\/td\u003e\n\u003ctd\u003eReceiver Overload\u003c\/td\u003e\n\u003ctd\u003e4dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Power Consumption\u003c\/td\u003e\n\u003ctd\u003e16.5W\u003c\/td\u003e\n\u003ctd\u003eExtinction Ratio\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;3.5dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDDM\/DOM\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003ctd\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation (Electrical)\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003ctd\u003eModulation (Optical)\u003c\/td\u003e\n\u003ctd\u003eDual 4×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCDR (Clock and Data Recovery)\u003c\/td\u003e\n\u003ctd\u003eTX and RX Built-in DSP\u003c\/td\u003e\n\u003ctd\u003ePackaging Technology\u003c\/td\u003e\n\u003ctd\u003eCOB (Chip on Board) Packaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBit Error Ratio (BER)\u003c\/td\u003e\n\u003ctd\u003e2.4E-4\u003c\/td\u003e\n\u003ctd\u003eMTBF\u003c\/td\u003e\n\u003ctd\u003e3,222,983 Hours (@40°C, 60% CL)\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n1,632,641 Hours (@40°C, 90% CL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3ck, IEEE 802.3cu-2021, OSFP MSA, CMIS Rev 5.0\u003c\/td\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48317168484489,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/OSFP800-XDR8-B2.jpg?v=1789022909"},{"product_id":"0-5m-2ft-generic-compatible-800g-qsfp-dd-8-x-100g-pam4-passive-copper-twinax-cable","title":"0.5m (2ft) Generic Compatible 800G QSFP-DD 8 x 100G PAM4 Passive Copper Twinax Cable","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eGeneric Compatible 800G QSFP-DD Passive Direct Attach Copper Twinax Cable (0.5-meter, QSFP-DD to QSFP-DD, 30AWG)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe Generic compatible 800G QSFP-DD DAC is designed for use in 800G Ethernet applications. It contains 8 high-speed differential pairs (lanes), each operating at data rates of up to 100Gb\/s. This cable is compliant with IEEE 802.3ck Ethernet standard and QSFP-DD MSA (Multi-Source Agreement).\u003cbr\u003eWith the advantages of low cost, low power consumption, interchangeability, etc, it is an ideal solution for short-distance interconnects and enable higher port bandwidth, density and configurability between data center racks. It also offers a more cost-effective solution than deploying discrete QSFP-DD modules with separate patch cords.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003ctable style=\"width: 99.9369%; height: 215.504px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003cth style=\"width: 28.8665%; height: 19.5913px;\"\u003ePart Number\u003c\/th\u003e\n\u003cth style=\"width: 34.0954%; height: 19.5913px;\"\u003eQDD-800G-PC005\u003c\/th\u003e\n\u003cth style=\"width: 18.568%; height: 19.5913px;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"width: 14.1747%; height: 19.5913px;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 19.5913px;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 19.5913px;\"\u003eQSFP-DD to QSFP-DD\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 19.5913px;\"\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 19.5913px;\"\u003e800Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 19.5913px;\"\u003eMedia\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 19.5913px;\"\u003eCopper\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 19.5913px;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 19.5913px;\"\u003ePassive DAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 19.5913px;\"\u003eCable Length\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 19.5913px;\"\u003e0.5m (2ft)\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 19.5913px;\"\u003eJacket Material\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 19.5913px;\"\u003ePVC (OFNR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 19.5913px;\"\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 19.5913px;\"\u003e69mm\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 19.5913px;\"\u003eWire AWG\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 19.5913px;\"\u003e30AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1826px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 39.1826px;\"\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 39.1826px;\"\u003e0.005W Per End\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 39.1826px;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 39.1826px;\"\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1826px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 39.1826px;\"\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 39.1826px;\"\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 39.1826px;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 39.1826px;\"\u003e800G Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1826px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 39.1826px;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 39.1826px;\"\u003eQSFP-DD MSA, CMIS Rev4.0, IEEE 802.3ck\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 39.1826px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 39.1826px;\"\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48361914433673,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/QDD-800G-PC01.png?v=1789626897"},{"product_id":"1m-3ft-generic-compatible-800g-qsfp-dd-8-x-100g-pam4-passive-copper-twinax-cable","title":"1m (3ft) Generic Compatible 800G QSFP-DD 8 x 100G PAM4 Passive Copper Twinax Cable","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eGeneric Compatible 800G QSFP-DD Passive Direct Attach Copper Twinax Cable (1-meter, QSFP-DD to QSFP-DD, 28AWG)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe Generic compatible 800G QSFP-DD DAC is designed for use in 800G Ethernet applications. It contains 8 high-speed differential pairs (lanes), each operating at data rates of up to 100Gb\/s. This cable is compliant with IEEE 802.3ck Ethernet standard and QSFP-DD MSA (Multi-Source Agreement).\u003cbr\u003eWith the advantages of low cost, low power consumption, interchangeability, etc, it is an ideal solution for short-distance interconnects and enable higher port bandwidth, density and configurability between data center racks. It also offers a more cost-effective solution than deploying discrete QSFP-DD modules with separate patch cords.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003ePart Number\u003c\/th\u003e\n\u003cth\u003eQDD-800G-PC01\u003c\/th\u003e\n\u003cth\u003eVendor Name\u003c\/th\u003e\n\u003cth\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eQSFP-DD to QSFP-DD\u003c\/td\u003e\n\u003ctd\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd\u003e800Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003ePassive DAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1m (3ft)\u003c\/td\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003ePVC (OFNR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e81mm\u003c\/td\u003e\n\u003ctd\u003eWire AWG\u003c\/td\u003e\n\u003ctd\u003e28AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd\u003e0.005W Per End\u003c\/td\u003e\n\u003ctd\u003eModulation Format\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003e800G Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eQSFP-DD MSA, CMIS Rev4.0, IEEE 802.3ck\u003c\/td\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48361923772553,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/QDD-800G-PC01.png?v=1789626897"},{"product_id":"1-5m-5ft-generic-compatible-800g-qsfp-dd-8-x-100g-pam4-passive-copper-twinax-cable","title":"1.5m (5ft) Generic Compatible 800G QSFP-DD 8 x 100G PAM4 Passive Copper Twinax Cable","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eGeneric Compatible 800G QSFP-DD Passive Direct Attach Copper Twinax Cable (1.5-meter, QSFP-DD to QSFP-DD, 28AWG)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe Generic compatible 800G QSFP-DD DAC is designed for use in 800G Ethernet applications. It contains 8 high-speed differential pairs (lanes), each operating at data rates of up to 100Gb\/s. This cable is compliant with IEEE 802.3ck Ethernet standard and QSFP-DD MSA (Multi-Source Agreement).\u003cbr\u003eWith the advantages of low cost, low power consumption, interchangeability, etc, it is an ideal solution for short-distance interconnects and enable higher port bandwidth, density and configurability between data center racks. It also offers a more cost-effective solution than deploying discrete QSFP-DD modules with separate patch cords.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003ctable style=\"width: 99.9369%; height: 214.504px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003cth style=\"width: 28.8665%; height: 19.5913px;\"\u003ePart Number\u003c\/th\u003e\n\u003cth style=\"width: 34.0954%; height: 19.5913px;\"\u003e\u003cspan\u003eQDD-800G-PC015\u003c\/span\u003e\u003c\/th\u003e\n\u003cth style=\"width: 18.568%; height: 19.5913px;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"width: 14.1747%; height: 19.5913px;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 19.5913px;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 19.5913px;\"\u003eQSFP-DD to QSFP-DD\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 19.5913px;\"\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 19.5913px;\"\u003e800Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 19.5913px;\"\u003eMedia\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 19.5913px;\"\u003eCopper\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 19.5913px;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 19.5913px;\"\u003ePassive DAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 18.5913px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 18.5913px;\"\u003eCable Length\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 18.5913px;\"\u003e\u003cspan\u003e1.5m (5ft)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 18.5913px;\"\u003eJacket Material\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 18.5913px;\"\u003ePVC (OFNR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 19.5913px;\"\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 19.5913px;\"\u003e69mm\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 19.5913px;\"\u003eWire AWG\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 19.5913px;\"\u003e30AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1826px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 39.1826px;\"\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 39.1826px;\"\u003e0.005W Per End\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 39.1826px;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 39.1826px;\"\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1826px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 39.1826px;\"\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 39.1826px;\"\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 39.1826px;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 39.1826px;\"\u003e800G Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1826px;\"\u003e\n\u003ctd style=\"width: 28.8665%; height: 39.1826px;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"width: 34.0954%; height: 39.1826px;\"\u003eQSFP-DD MSA, CMIS Rev4.0, IEEE 802.3ck\u003c\/td\u003e\n\u003ctd style=\"width: 18.568%; height: 39.1826px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 14.1747%; height: 39.1826px;\"\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48361973153929,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/QDD-800G-PC01.png?v=1789626897"},{"product_id":"0-5m-2ft-arista-networks-c-o800-o800-0-5m-compatible-800g-osfp-8-x-100g-pam4-ihs-finned-top-passive-copper-twinax-cable","title":"0.5m (2ft) Arista Networks C-O800-O800-0.5M Compatible 800G OSFP 8 x 100G PAM4 IHS\/Finned Top Passive Copper Twinax Cable","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eArista Networks C-O800-O800-0.5M Compatible 800G OSFP IHS\/Finned Top DAC Twinax Cable (0.5-meter, Passive, OSFP to OSFP, 30AWG)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe Arista Networks C-O800-O800-0.5M is a 2x 400Gb\/s twin-port OSFP (Octal Small Form-factor Pluggable) to 2x 400Gb\/s twin-port OSFP direct attach cable that operates over passive copper and integrates eight high-speed electrical pairs, each supporting up to 100Gb\/s with 100G-PAM4 modulation to deliver 800Gb\/s for short-reach links. This cable is compliant with OSFP MSA (Multi-Source Agreement), CMIS Rev 4.0, and IEEE 802.3ck standards.\u003cbr\u003eBoth ends use a IHS\/finned top design optimized for air-cooled switches. With near-zero power, ultra-low latency, and plug-and-play deployment, this passive DAC is ideal for short-reach, switch-to-switch connections in spine-leaf or leaf-leaf architectures, providing a cost-efficient and power-optimized solution for AI, HPC, and cloud data centers.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eNote: \"Finned top\" transceivers are now called \"Integrated Heat Sink\" (IHS) as the cooling fins are integrated into the OSFP connector metal top. Commonly used in air-cooled switches.\u003cbr\u003e\"Flat top\" transceivers are now called \"Riding Heat Sink\" (RHS) as the cooling fins ride on top of the network card or system's internal cages. This is used for both air-cooled and liquid-cooled applications for DGX, ConnectX-7, and BlueField-3 DPUS.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eArista Networks Compatible\u003c\/th\u003e\n\u003cth\u003eC-O800-O800-0.5M\u003c\/th\u003e\n\u003cth\u003eVendor Name\u003c\/th\u003e\n\u003cth\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eOSFP (IHS\/Finned Top) to OSFP (IHS\/Finned Top)\u003c\/td\u003e\n\u003ctd\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd\u003e800Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003ePassive DAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e0.5m (2ft)\u003c\/td\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003ePET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e54mm\u003c\/td\u003e\n\u003ctd\u003eWire AWG\u003c\/td\u003e\n\u003ctd\u003e30AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd\u003e0.1W Per End\u003c\/td\u003e\n\u003ctd\u003eModulation Format\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003e800G Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3ck, CMIS v4.0\u003c\/td\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48362055729289,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/C-O800-O800-0.5M.png?v=1789629370"},{"product_id":"1m-3ft-arista-networks-c-o800-o800-1m-compatible-800g-osfp-8-x-100g-pam4-ihs-finned-top-passive-copper-twinax-cable","title":"1m (3ft) Arista Networks C-O800-O800-1M Compatible 800G OSFP 8 x 100G PAM4 IHS\/Finned Top Passive Copper Twinax Cable","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eArista Networks C-O800-O800-1M Compatible 800G OSFP IHS\/Finned Top DAC Twinax Cable (1-meter, Passive, OSFP to OSFP, 30AWG)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe Arista Networks C-O800-O800-1M is a 2x 400Gb\/s twin-port OSFP (Octal Small Form-factor Pluggable) to 2x 400Gb\/s twin-port OSFP direct attach cable that operates over passive copper and integrates eight high-speed electrical pairs, each supporting up to 100Gb\/s with 100G-PAM4 modulation to deliver 800Gb\/s for short-reach links. This cable is compliant with OSFP MSA (Multi-Source Agreement), CMIS Rev 4.0, and IEEE 802.3ck standards.\u003cbr\u003eBoth ends use a IHS\/finned top design optimized for air-cooled switches. With near-zero power, ultra-low latency, and plug-and-play deployment, this passive DAC is ideal for short-reach, switch-to-switch connections in spine-leaf or leaf-leaf architectures, providing a cost-efficient and power-optimized solution for AI, HPC, and cloud data centers.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eNote: \"Finned top\" transceivers are now called \"Integrated Heat Sink\" (IHS) as the cooling fins are integrated into the OSFP connector metal top. Commonly used in air-cooled switches.\u003cbr\u003e\"Flat top\" transceivers are now called \"Riding Heat Sink\" (RHS) as the cooling fins ride on top of the network card or system's internal cages. This is used for both air-cooled and liquid-cooled applications for DGX, ConnectX-7, and BlueField-3 DPUS.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eArista Networks Compatible\u003c\/th\u003e\n\u003cth\u003eC-O800-O800-1M\u003c\/th\u003e\n\u003cth\u003eVendor Name\u003c\/th\u003e\n\u003cth\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eOSFP (IHS\/Finned Top) to OSFP (IHS\/Finned Top)\u003c\/td\u003e\n\u003ctd\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd\u003e800Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003ePassive DAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1m (3ft)\u003c\/td\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003ePET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e54mm\u003c\/td\u003e\n\u003ctd\u003eWire AWG\u003c\/td\u003e\n\u003ctd\u003e30AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd\u003e0.1W Per End\u003c\/td\u003e\n\u003ctd\u003eModulation Format\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003e800G Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3ck, CMIS v4.0\u003c\/td\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48362067558537,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/C-O800-O800-0.5M.png?v=1789629370"},{"product_id":"1-5m-5ft-arista-networks-c-o800-o800-1-5m-compatible-800g-osfp-8-x-100g-pam4-ihs-finned-top-passive-copper-twinax-cable","title":"1.5m (5ft) Arista Networks C-O800-O800-1.5M Compatible 800G OSFP 8 x 100G PAM4 IHS\/Finned Top Passive Copper Twinax Cable","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eArista Networks C-O800-O800-1.5M Compatible 800G OSFP IHS\/Finned Top DAC Twinax Cable (1.5-meter, Passive, OSFP to OSFP, 26AWG)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe Arista Networks C-O800-O800-1.5M is a 2x 400Gb\/s twin-port OSFP (Octal Small Form-factor Pluggable) to 2x 400Gb\/s twin-port OSFP direct attach cable that operates over passive copper and integrates eight high-speed electrical pairs, each supporting up to 100Gb\/s with 100G-PAM4 modulation to deliver 800Gb\/s for short-reach links. This cable is compliant with OSFP MSA (Multi-Source Agreement), CMIS Rev 4.0, and IEEE 802.3ck standards.\u003cbr\u003eBoth ends use a IHS\/finned top design optimized for air-cooled switches. With near-zero power, ultra-low latency, and plug-and-play deployment, this passive DAC is ideal for short-reach, switch-to-switch connections in spine-leaf or leaf-leaf architectures, providing a cost-efficient and power-optimized solution for AI, HPC, and cloud data centers.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eNote: \"Finned top\" transceivers are now called \"Integrated Heat Sink\" (IHS) as the cooling fins are integrated into the OSFP connector metal top. Commonly used in air-cooled switches.\u003cbr\u003e\"Flat top\" transceivers are now called \"Riding Heat Sink\" (RHS) as the cooling fins ride on top of the network card or system's internal cages. This is used for both air-cooled and liquid-cooled applications for DGX, ConnectX-7, and BlueField-3 DPUS.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eArista Networks Compatible\u003c\/th\u003e\n\u003cth\u003eC-O800-O800-1.5M\u003c\/th\u003e\n\u003cth\u003eVendor Name\u003c\/th\u003e\n\u003cth\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eOSFP (IHS\/Finned Top) to OSFP (IHS\/Finned Top)\u003c\/td\u003e\n\u003ctd\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd\u003e800Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003ePassive DAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e1.5m (5ft)\u003c\/td\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003ePET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e69mm\u003c\/td\u003e\n\u003ctd\u003eWire AWG\u003c\/td\u003e\n\u003ctd\u003e26AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd\u003e0.1W Per End\u003c\/td\u003e\n\u003ctd\u003eModulation Format\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003e800G Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3ck, CMIS v4.0\u003c\/td\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48362074898569,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/C-O800-O800-0.5M.png?v=1789629370"},{"product_id":"2m-7ft-arista-networks-c-o800-o800-2m-compatible-800g-osfp-8-x-100g-pam4-ihs-finned-top-passive-copper-twinax-cable","title":"2m (7ft) Arista Networks C-O800-O800-2M Compatible 800G OSFP 8 x 100G PAM4 IHS\/Finned Top Passive Copper Twinax Cable","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eArista Networks C-O800-O800-2M Compatible 800G OSFP IHS\/Finned Top DAC Twinax Cable (2-meter, Passive, OSFP to OSFP, 26AWG)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe Arista Networks C-O800-O800-2M is a 2x 400Gb\/s twin-port OSFP (Octal Small Form-factor Pluggable) to 2x 400Gb\/s twin-port OSFP direct attach cable that operates over passive copper and integrates eight high-speed electrical pairs, each supporting up to 100Gb\/s with 100G-PAM4 modulation to deliver 800Gb\/s for short-reach links. This cable is compliant with OSFP MSA (Multi-Source Agreement), CMIS Rev 4.0, and IEEE 802.3ck standards.\u003cbr\u003eBoth ends use a IHS\/finned top design optimized for air-cooled switches. With near-zero power, ultra-low latency, and plug-and-play deployment, this passive DAC is ideal for short-reach, switch-to-switch connections in spine-leaf or leaf-leaf architectures, providing a cost-efficient and power-optimized solution for AI, HPC, and cloud data centers.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eNote: \"Finned top\" transceivers are now called \"Integrated Heat Sink\" (IHS) as the cooling fins are integrated into the OSFP connector metal top. Commonly used in air-cooled switches.\u003cbr\u003e\"Flat top\" transceivers are now called \"Riding Heat Sink\" (RHS) as the cooling fins ride on top of the network card or system's internal cages. This is used for both air-cooled and liquid-cooled applications for DGX, ConnectX-7, and BlueField-3 DPUS.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eArista Networks Compatible\u003c\/th\u003e\n\u003cth\u003eC-O800-O800-2M\u003c\/th\u003e\n\u003cth\u003eVendor Name\u003c\/th\u003e\n\u003cth\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eOSFP (IHS\/Finned Top) to OSFP (IHS\/Finned Top)\u003c\/td\u003e\n\u003ctd\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd\u003e800Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003ePassive DAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e2m (7ft)\u003c\/td\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003ePET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e69mm\u003c\/td\u003e\n\u003ctd\u003eWire AWG\u003c\/td\u003e\n\u003ctd\u003e26AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd\u003e0.1W Per End\u003c\/td\u003e\n\u003ctd\u003eModulation Format\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003e800G Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3ck, CMIS v4.0\u003c\/td\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48362084368521,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/C-O800-O800-0.5M.png?v=1789629370"},{"product_id":"3m-10ft-arista-networks-c-o800-o800-3m-compatible-800g-osfp-8-x-100g-pam4-ihs-finned-top-passive-copper-twinax-cable","title":"3m (10ft) Arista Networks C-O800-O800-3M Compatible 800G OSFP 8 x 100G PAM4 IHS\/Finned Top Passive Copper Twinax Cable","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eArista Networks C-O800-O800-3M Compatible 800G OSFP IHS\/Finned Top DAC Twinax Cable (3-meter, Passive, OSFP to OSFP, 26AWG)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe Arista Networks C-O800-O800-3M is a 2x 400Gb\/s twin-port OSFP (Octal Small Form-factor Pluggable) to 2x 400Gb\/s twin-port OSFP direct attach cable that operates over passive copper and integrates eight high-speed electrical pairs, each supporting up to 100Gb\/s with 100G-PAM4 modulation to deliver 800Gb\/s for short-reach links. This cable is compliant with OSFP MSA (Multi-Source Agreement), CMIS Rev 4.0, and IEEE 802.3ck standards.\u003cbr\u003eBoth ends use a IHS\/finned top design optimized for air-cooled switches. With near-zero power, ultra-low latency, and plug-and-play deployment, this passive DAC is ideal for short-reach, switch-to-switch connections in spine-leaf or leaf-leaf architectures, providing a cost-efficient and power-optimized solution for AI, HPC, and cloud data centers.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eNote: \"Finned top\" transceivers are now called \"Integrated Heat Sink\" (IHS) as the cooling fins are integrated into the OSFP connector metal top. Commonly used in air-cooled switches.\u003cbr\u003e\"Flat top\" transceivers are now called \"Riding Heat Sink\" (RHS) as the cooling fins ride on top of the network card or system's internal cages. This is used for both air-cooled and liquid-cooled applications for DGX, ConnectX-7, and BlueField-3 DPUS.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eArista Networks Compatible\u003c\/th\u003e\n\u003cth\u003eC-O800-O800-3M\u003c\/th\u003e\n\u003cth\u003eVendor Name\u003c\/th\u003e\n\u003cth\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eOSFP (IHS\/Finned Top) to OSFP (IHS\/Finned Top)\u003c\/td\u003e\n\u003ctd\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd\u003e800Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eCopper\u003c\/td\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003ePassive DAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3m (10ft)\u003c\/td\u003e\n\u003ctd\u003eJacket Material\u003c\/td\u003e\n\u003ctd\u003ePET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Bend Radius\u003c\/td\u003e\n\u003ctd\u003e69mm\u003c\/td\u003e\n\u003ctd\u003eWire AWG\u003c\/td\u003e\n\u003ctd\u003e26AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd\u003e0.1W Per End\u003c\/td\u003e\n\u003ctd\u003eModulation Format\u003c\/td\u003e\n\u003ctd\u003e8×100G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003e800G Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eOSFP MSA, IEEE 802.3ck, CMIS v4.0\u003c\/td\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48362097082505,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/C-O800-O800-0.5M.png?v=1789629370"}],"url":"https:\/\/www.fibersoon.com\/collections\/800g-qsfp-dd-osfp.oembed?page=2","provider":"F-tone Networks","version":"1.0","type":"link"}