{"title":"Fiber Protection Systems","description":null,"products":[{"product_id":"ft-olp-4u","title":"Empty 4U Rackmount Chassis To Hold 8 Pieces Optical Link Protection OLP Card","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OLP-4U\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e 4U Empty Rackmount Chassis To Hold 8 Pieces Optical Link Protection OLP Card\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e 4U Rack Chassis Carrier-Class Optical Protection Platform\u003c\/h3\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e F-tone’s 4U rack chassis FT-OLP-4U is a carrier class platform supporting a family of modular optical protection systems offering high versatility, extensibility, availability and port density. The result is cost-effective protection architecture, to meet the needs of carriers, IXC, private network operators and enterprises.\u003cbr\u003e \u003cbr\u003e The 4U rack-mountable chassis containing 8 slots can hosts a variety of hot-swappable optical protection modules (OLP Cards), one or two redundant power supplies and control modules. The modular architecture of the FT-OLP-4U rack chassis offers low up-front cost and allows user to expand the system as their needs increase.\u003cbr\u003e Key Features\u003c\/p\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e 4U configuration supports up to 8 protection modules\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Hot swappable plug in modules\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e SNMP Remote network management\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Dual Power supply\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Peak performance and increased security\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Supports various protection schemes and applications within the same platform\u003c\/li\u003e \u003cbr\u003e Application\u003cbr\u003e \u003cli style=\"margin:4px 0;\"\u003e Dedicated protection applications: Fiber Link, equipment and optical channel (OCh)\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Shared protection applications\u003c\/li\u003e \u003cbr\u003e Dimension\u003cbr\u003e \u003c\/ul\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e For more detailed information or any custom requirements, please contact with F-tone sales team at [email protected].\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003c\/p\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSlots\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eColor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSilver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSwitch\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePower ON\/OFF, Alarm \u0026amp; Systen reset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCooling fans\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWith\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eA C 220V (Range: 100V~276V)\u003cbr\u003e DC 48V (Range: -35V~70V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eInsertion Loss\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;1.5dB (1:1 protected)\u003cbr\u003e \u0026lt;4.5dB (1+1 protected)\u003cbr\u003e \u0026lt;1.5dB (1-1 protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0~55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-20~+60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e5%~95% no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e483mm(W) x 300mm(D) x 177mm(H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr type=\"_moz\"\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48271527346313,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm7308-0.jpg?v=1788483461"},{"product_id":"ft-olp-c","title":"Link Protection Card","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OLP-C\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Link Protection Card\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Optical Link Protection Card for Fiber Protection, Bi-directional protection in SMF, 1RU Rack Chassis\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Link protection helps to ensure that traffic going over a specific interface to a neighboring router or switch can continue to reach this router (switch) if that interface fails. When link protection is configured for an interface and an LSP that traverses this interface, backup tunnel is created that will handle this traffic if the interface fails. This enables all traffic carried by LSPs that traverse a failed link to be rerouted around the failure. The reroute decision is completely controlled locally by the router interfacing the failed link.\u003cbr\u003e \u003cbr\u003e F-tone’s FT-OLP-C is a link protection card. It can be installed into FT-P-OTP800 series transport platform for more capacity solution in limited environment. If a link-protected interface fails, traffic is quickly switched to the Backup tunnel. Backup tunnel uses a different interface and path to reach the same destination. The path used can be configured explicitly, or you can rely on CSPF.\u003cbr\u003e \u003cbr\u003e Note that OLP should be used in pairs and a backup tunnel cannot share the same egress interface with the LSPs it monitors.\u003c\/p\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h2\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Key Features\u003c\/h2\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e 1:1, 1+1 and 1-1 protection for optional\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Less than 20ms automatic switch time\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Real-time monitoring link from link failure\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Support the working channel optical power show\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Dual hot redundancy power supply and hot-pluggable\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Allows users to adjust the decision threshold optical switching power\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Supports Fast, Gigabit and 10 Gigabit Ethernet fiber connections in SC\/ST\/FC\/LC connectors\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Switching threshold power and alarming threshold power can be set up by LCD screen or network management access\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e The main equipment at receiving site have three modes for switching: automatic, forced manual and remote control\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Designed with excellent heat dissipation and temperature adaptability, it can be applied in various complicated environments\u003c\/li\u003e \u003c\/ul\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h2\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Front Panel Appearance\u003c\/h2\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e LCD Display Board: Displaying the relevant information, such as the working Mode; Current Running Optical Line; Optical Power Value of the transmission device; Reverse conditions…etc\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e RJ45 Ethernet Interface RJ45 Ethernet Interface for access to the Ethernet network; remote management; supporting remote graphical window management\u003c\/li\u003e \u003cbr\u003e \u003cli style=\"margin:4px 0;\"\u003e Enter (Esc): The button to log in and log out of the LCD menu. Press it to exit the menu or to confirm; Long press to exit the menu or cancel the setting.\u003c\/li\u003e ▲▼：Use them to move-up and down or modify the parameters on the menu.\u003cbr\u003e \u003cli style=\"margin:4px 0;\"\u003e Optical interface introduction: There are 6 optical interfaces on the device’s control panel: T1, R1, T2, R2, T3 and R3.\u003c\/li\u003e \u003cbr\u003e Link Protection Card for Packet-Optical Transport Platform\u003cbr\u003e \u003c\/ul\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cbr\u003e In this illustration, the FT-P-OTP800-4S transport platform installed 2 pieces node protection card FT-OLP-C and 1 piece control card. One FT-OLP-C occupies one slot.\u003cbr\u003e \u003cbr\u003e Valid Slots in the Sub-racks\u003cbr\u003e a. In the FT-P-OTP800-2S, valid slots are Slot 1 and Slot 2\u003cbr\u003e b. In the FT-P-OTP800-4S, valid slots are Slot 2 and Slot 4\u003cbr\u003e c. In the FT-P-OTP800-11S, valid slots are Slot 2 and Slot 10\u003cbr\u003e Protection Illustration\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e It shows an example of how you can implement link protection based on 1+1 protection operation. In 1+1 operation, a splitter bridge sends the Tx signal to both line (the main line and the backup line) and a 2x1 selector switch selects the signal from one of the line. In default mode, traffic from the main line is selected. When link failures, the selector near the Rx side of the failed traffic detects the failure, switches over, and selects the traffic from the backup line.\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e It shows an example of how you can implement link protection based on 1:1 protection operation. The 1:1 protection adopts 2x2 optical switch technologies. If the link between two transmission equipment fails, traffic is quickly switched to the backup line generated by link protection.\u003cbr\u003e \u003cbr\u003e For more detailed information or any custom requirements, please contact with F-tone sales team at [email protected].\u003c\/p\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h2\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:683px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003ePerformance\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eParameter\u003c\/th\u003e\n\u003ctd style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelengthRange(unit: nm)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1310±50nm \u0026amp; 1550±50nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMonitoringRangeofOpticalPower(unit: dBm)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-35～+25(TX)\u003cbr\u003e -50～+10(RS)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eInsertionLoss(unit; dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1+1Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤4.0dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤1.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1:1Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤1.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eBPBypassProtection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤1.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSRProtection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤1.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReturnLoss(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≥45dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCrosstalk(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≥55dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOpticalPowerResolution(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.1dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOpticalPowerMeasurementAccuracy(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.5dB(＋25dBm～-40dBm)\u003cbr\u003e ≤1.0dB(-40dBm～-50dBm)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelengthDependentLoss(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.25dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePolarizationDependentLoss(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.1dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSwitchingTime(unit: ms)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1+1 protect ≤15ms\u003cbr\u003e 1:1 protect ≤20ms\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePDL(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.1\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum optical power load(unit: mW)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e300\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr type=\"_moz\"\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48274321834121,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}]},{"product_id":"ft-olp-4u-c","title":"Link Protection Card for 4U Rack Chassis","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OLP-4U-C\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Link Protection Card for 4U Rack Chassis\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Line Card OLP For 4RU Rack chassis\u003c\/h3\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Link protection helps to ensure that traffic going over a specific interface to a neighboring router or switch can continue to reach this router (switch) if that interface fails. When link protection is configured for an interface and an LSP that traverses this interface, backup tunnel is created that will handle this traffic if the interface fails. This enables all traffic carried by LSPs that traverse a failed link to be rerouted around the failure. The reroute decision is completely controlled locally by the router interfacing the failed link.\u003cbr\u003e \u003cbr\u003e F-tone’s FT-OLP-4U-C is a link protection card. It can be installed into 4UR rack chassis series transport platform for more capacity solution in limited environment. If a link-protected interface fails, traffic is quickly switched to the Backup tunnel. Backup tunnel uses a different interface and path to reach the same destination. The path used can be configured explicitly, or you can rely on CSPF.\u003cbr\u003e \u003cbr\u003e Note that OLP should be used in pairs and a backup tunnel cannot share the same egress interface with the LSPs it monitors.\u003c\/p\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h2\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Key Features\u003c\/h2\u003e \u003cbr\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e 1:1, 1+1 and 1-1 protection for optional\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Less than 20ms automatic switch time\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Real-time monitoring link from link failure\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Support the working channel optical power show\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Dual hot redundancy power supply and hot-pluggable\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Allows users to adjust the decision threshold optical switching power\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Supports Fast, Gigabit and 10 Gigabit Ethernet fiber connections in SC\/ST\/FC\/LC connectors\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Switching threshold power and alarming threshold power can be set up by LCD screen or network management access\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e The main equipment at receiving site have three modes for switching: automatic, forced manual and remote control\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Designed with excellent heat dissipation and temperature adaptability, it can be applied in various complicated environments\u003c\/li\u003e \u003c\/ul\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h2\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Front Panel Appearance\u003c\/h2\u003e \u003cbr\u003e \u003cbr\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e LCD Display Board: Displaying the relevant information, such as the working Mode; Current Running Optical Line; Optical Power Value of the transmission device; Reverse conditions…etc\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e RJ45 Ethernet Interface RJ45 Ethernet Interface for access to the Ethernet network; remote management; supporting remote graphical window management\u003c\/li\u003e \u003cbr\u003e \u003cli style=\"margin:4px 0;\"\u003e (Enter (Esc): The button to log in and log out of the LCD menu. Press it to exit the menu or to confirm; Long press to exit the menu or cancel the setting.\u003c\/li\u003e ▲▼：Use them to move-up and down or modify the parameters on the menu.\u003cbr\u003e \u003cli style=\"margin:4px 0;\"\u003e Optical interface introduction: There are 6 optical interfaces on the device’s control panel: T1, R1, T2, R2, T3 and R3.\u003c\/li\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e Link Protection Card for Packet-Optical Transport Platform\u003cbr\u003e \u003c\/ul\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cbr\u003e -4U transport platform installed 8 pieces link protection card FT-OLP-4U-C .\u003cbr\u003e \u003cbr\u003e Protection Illustration\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e It shows an example of how you can implement link protection based on 1+1 protection operation. In 1+1 operation, a splitter bridge sends the Tx signal to both line (the main line and the backup line) and a 2x1 selector switch selects the signal from one of the line. In default mode, traffic from the main line is selected. When link failures, the selector near the Rx side of the failed traffic detects the failure, switches over, and selects the traffic from the backup line.\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e It shows an example of how you can implement link protection based on 1:1 protection operation. The 1:1 protection adopts 2x2 optical switch technologies. If the link between two transmission equipment fails, traffic is quickly switched to the backup line generated by link protection.\u003cbr\u003e \u003cbr\u003e For more detailed information or any custom requirements, please contact with F-tone sales team at [email protected].\u003c\/p\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h2\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:683px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003ePerformance\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eParameter\u003c\/th\u003e\n\u003ctd style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelengthRange(unit: nm)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1310±50nm \u0026amp; 1550±50nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMonitoringRangeofOpticalPower(unit: dBm)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-35～+25(TX)\u003cbr\u003e -50～+10(RS)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eInsertionLoss(unit; dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1+1Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤4.0dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤1.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1:1Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤1.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eBPBypassProtection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤1.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSRProtection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤1.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReturnLoss(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≥45dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCrosstalk(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≥55dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOpticalPowerResolution(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.1dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOpticalPowerMeasurementAccuracy(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.5dB(＋25dBm～-40dBm)\u003cbr\u003e ≤1.0dB(-40dBm～-50dBm)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelengthDependentLoss(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.25dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePolarizationDependentLoss(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.1dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSwitchingTime(unit: ms)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1+1 protect ≤15ms\u003cbr\u003e 1:1 protect ≤20ms\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePDL(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.1\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum optical power load(unit: mW)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e300\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr type=\"_moz\"\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48274324684937,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}]},{"product_id":"ft-olp-s","title":"Link Protection Platform","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OLP-S\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Link Protection Platform\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Optical Link Protection Platform for Fiber Protection, Bi-directional protection in SMF, 1RU Rack Chassis\u003c\/h3\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Link protection helps to ensure that traffic going over a specific interface to a neighboring router or switch can continue to reach this router (switch) if that interface fails. When link protection is configured for an interface and an LSP that traverses this interface, backup tunnel is created that will handle this traffic if the interface fails. This enables all traffic carried by LSPs that traverse a failed link to be rerouted around the failure. The reroute decision is completely controlled locally by the router interfacing the failed link.\u003cbr\u003e \u003cbr\u003e If a link-protected interface fails, traffic is quickly switched to the Backup tunnel. Backup tunnel uses a different interface and path to reach the same destination. The path used can be configured explicitly, or you can rely on CSPF.\u003cbr\u003e \u003cbr\u003e Note that OLP should be used in pairs and a backup tunnel cannot share the same egress interface with the LSPs it monitors.\u003cbr\u003e Key Features\u003c\/p\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e 1:1, 1+1 and 1-1 protection for optional\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Less than 20ms automatic switch time\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Real-time monitoring link from link failure\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Support the working channel optical power show\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Dual hot redundancy power supply and hot-pluggable\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Allows users to adjust the decision threshold optical switching power\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Supports Fast, Gigabit and 10 Gigabit Ethernet fiber connections in SC\/ST\/FC\/LC connectors\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Switching threshold power and alarming threshold power can be set up by LCD screen or network management access\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e The main equipment at receiving site have three modes for switching: automatic, forced manual and remote control\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Designed with excellent heat dissipation and temperature adaptability, it can be applied in various complicated environments\u003c\/li\u003e \u003cbr\u003e Front Panel Appearance\u003cbr\u003e \u003c\/ul\u003e \u003cbr\u003e \u003cbr\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e LCD Display Board: Displaying the relevant information, such as the working Mode; Current Running Optical Line; Optical Power Value of the transmission device; Reverse conditions…etc\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e RJ45 Ethernet Interface RJ45 Ethernet Interface for access to the Ethernet network; remote management; supporting remote graphical window management\u003c\/li\u003e \u003cbr\u003e \u003cli style=\"margin:4px 0;\"\u003e The button to log in and log out of the LCD menu. Press it to exit the menu or to confirm; Long press to exit the menu or cancel the setting.\u003c\/li\u003e ▲▼：Use them to move-up and down or modify the parameters on the menu.\u003cbr\u003e \u003cli style=\"margin:4px 0;\"\u003e Optical interface introduction: There are 6 optical interfaces on the device’s control panel: T1, R1, T2 , R2, T3 and R3.\u003c\/li\u003e \u003cbr\u003e Protection Illustration\u003cbr\u003e \u003c\/ul\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cbr\u003e \u003cbr\u003e It shows an example of how you can implement link protection based on 1+1 protection operation. In 1+1 operation, a splitter bridge sends the Tx signal to both line (the main line and the backup line) and a 2x1 selector switch selects the signal from one of the line. In default mode, traffic from the main line is selected. When link failures, the selector near the Rx side of the failed traffic detects the failure, switches over, and selects the traffic from the backup line.\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e It shows an example of how you can implement link protection based on 1:1 protection operation. The 1:1 protection adopts 2x2 optical switch technologies. If the link between two transmission equipment fails, traffic is quickly switched to the backup line generated by link protection.\u003cbr\u003e \u003cbr\u003e For more detailed information or any custom requirements, please contact with F-tone sales team at [email protected].\u003c\/p\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:683px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003ePerformance\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eParameter\u003c\/th\u003e\n\u003ctd style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelengthRange(unit: nm)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1310±50nm \u0026amp; 1550±50nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReturnLoss(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≥45dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eInsertionLoss(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1+1Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤4.0dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤1.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1:1Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤1.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eBPBypassProtection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤1.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSRProtection\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤1.5dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePDL(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤ 0.1\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOpticalPowerResolution(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.1dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ecrosstalk(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≥ 55dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOpticalPowerMeasurementAccuracy(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.5dB(+25~-40dBm)\u003cbr\u003e ≤1.0dB(-40~-50dBm)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eRange of optical power(unit: dBm)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-35～+25(TX)\u003cbr\u003e -50～+10 (RX)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength DependentLoss(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.25dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSwitchingTime(unit: ms)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤20ms\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eA C 220V\u003cbr\u003e DC 48V\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0~60°C\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-40~+85°C\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e5%~95% no condensation\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDimensions (unit: mm)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e440(W)*220(D)*44.5(H)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ecrosstalk(unit: dB)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≥ 55dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eManagement Mode\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConsole, Telnet, Network management Button \u0026amp; LCD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum optical power load(unit: mW)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e300\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSwitching time(unit: ms)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1:1 Protect\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤ 20\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1+1 Protect\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤ 15\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr type=\"_moz\"\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48274328125577,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}]},{"product_id":"ft-obp-s","title":"Node Protection Bypass System","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OBP-S\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Node Protection Bypass System\u003c\/h2\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Optical Bypass Protection System for Node Protection, Bi-directional protection in SMF, 1RU Rack Chassis\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Node protection is a intelligent optical switch system which can bypass fault node in optical transmission network to avoid breakdown of whole network communication. It can automatically switch by detecting the nodes optical power or signal failure. Therefore to ensure that traffic from an LSP traversing a neighboring router can continue to reach its destination even if the neighboring router fails.\u003cbr\u003e F-tone’s FT-OBP-S is a Standalone bypass protection equipment. In normal operations, the FT-OBP-S simply acts as a gateway that forwards network traffic to and from the network switch. However, if power is lost, the FT-OBP-S will bypass the unpowered switch and simply pass network traffic to the next switch in the relay. It is widely used in PDH, SDH, C\/DWDM, power communication and CATV systems for optical monitoring.\u003cbr\u003e Key Features\u003c\/p\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e 1:1, 1+1 and 1-1 protection for optional\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Less than 15ms automatic switch time\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e SNMP Remote network management\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Real-time monitoring nodes from nodes failure\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Dual hot redundancy power supply and hot-pluggable\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Supports Fast, Gigabit and 10 Gigabit Ethernet fiber connections in SC\/ST\/FC\/LC connectors\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Switching threshold power and alarming threshold power can be set up by LCD screen or network management access\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e The main equipment at receiving site have three modes for switching: automatic, forced manual and remote control\u003c\/li\u003e \u003cbr\u003e Front Panel Appearance\u003cbr\u003e \u003c\/ul\u003e \u003cbr\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e LCD Display Board: Displaying the relevant information, such as the working Mode; Current Running Optical Line; Optical Power Value of the transmission device; Reverse conditions…etc\u003c\/li\u003e \u003cbr\u003e \u003cli style=\"margin:4px 0;\"\u003e RJ45 Ethernet Interface RJ45 Ethernet Interface for access to the Ethernet network; remote management; supporting remote graphical window management\u003c\/li\u003e \u003cbr\u003e \u003cli style=\"margin:4px 0;\"\u003e Enter (Esc): The button to log in and log out of the LCD menu. Press it to exit the menu or to confirm; Long press to exit the menu or cancel the setting.\u003c\/li\u003e ▲▼：Use them to move-up and down or modify the parameters on the menu.\u003cbr\u003e \u003cli style=\"margin:4px 0;\"\u003e Optical interface introduction: There are 8 optical interfaces on the device’s control panel: T1, R1, T2, R2, T3, R3, T4 and R4.\u003c\/li\u003e Application Case\u003cbr\u003e \u003c\/ul\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cbr\u003e Protection Illustration\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e It shows an example of how you can implement node protection based on 1:1 protection operation. The 1:1 protection adopts 2x2 optical switch technologies. In default mode, the Tx signal towards the main line, through SDH\/ADM node equipment, and the selector chooses the Rx traffic from the main line. When the middle node failure, the network will bypass the failured node and automatically switch to backup line.\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e It shows an example of how you can implement node protection based on 1+1 protection operation. In 1+1 operation, a splitter bridge sends the Tx signal to both line (the main line and the backup line) and a 2x1 selector switch selects the signal from one of the line. In default mode, traffic from the main line is selected. In this illustration, SDH\/ADM act as an node between two transmission equipment. When the power failures, the selector near the Rx side of the failed traffic detects the failure, switches over, and selects the traffic from the backup line.\u003cbr\u003e \u003cbr\u003e For more detailed information or any custom requirements, please contact with F-tone sales team at [email protected].\u003c\/p\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:458px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003ePerformance\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eParameter\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelengthRange\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1310±50nm \u0026amp; 1550±50nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDynamicRangeofOpticalPower\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-50～+25dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReturnLoss\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≥45dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eInsertion Loss\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;1.5dB (1:1 protected)\u003cbr\u003e 4.5dB (1+1 protected)\u003cbr\u003e \u0026lt;1.5dB (1-1 protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOpticalPowerResolution\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.01dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOpticalPowerMeasurementAccuracy\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.5dB (-40~+25dBm)\u003cbr\u003e ≤1.0dB (-50~-40dBm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelengthDependentLoss\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.25dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePolarizationDependentLoss\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.1dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSwitchingTime\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤15ms (Typical: 5ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eLCD Displaying\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e160×32 Pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eA C 220V (Range: 100V~276V)\u003cbr\u003e DC 48V (Range: -35V~70V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-10~50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-40~+85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e5%~95% no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDimensions (unit: mm)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e440(W)*220(D)*44.5(H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eManagement Mode\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConsole, Telnet, Network management Button \u0026amp; LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEquipment interface\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1x RJ45 Ethernet Port\u003cbr\u003e 1x RS232 Console Port\u003cbr\u003e 8x Optical Port (LC-UPC by default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eNetworks Capability\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEMS GUI interface\u003cbr\u003e Remote Upgrading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr type=\"_moz\"\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48274828853385,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/ft-obp-s.jpg?v=1788653347"},{"product_id":"ft-obp-c","title":"Node Protection Card","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OBP-C\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Node Protection Card\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Optical Bypass Protection Card for Node Protection, Bi-directional protection in SMF, 1RU Rack Chassis\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Node protection is a intelligent optical switch system which can bypass fault node in optical transmission network to avoid breakdown of whole network communication. It can automatically switch by detecting the nodes optical power or signal failure. Therefore to ensure that traffic from an LSP traversing a neighboring router can continue to reach its destination even if the neighboring router fails.\u003cbr\u003e F-tone’s FT-OBP-C is a node protection card. It can be installed into FT-P-OTP800 series transport platform for more capacity solution in limited environment. The FT-OBP-C will bypass the unpowered switch and simply pass network traffic to the next switch in the relay. It is widely used in PDH, SDH, C\/DWDM, power communication and CATV systems for optical monitoring.\u003cbr\u003e Key Features\u003c\/p\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e 1:1, 1+1 and 1-1 protection for optional\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Less than 15ms automatic switch time\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Real-time monitoring nodes from nodes failure\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e It uses the insert plate structural design of Mini 0.5U, which is convenient for installation\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e The switching module is designed with simple and stable circuit, which is with high reliability\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Supports multiple management modes such as Console, SNMP as well as button assignment\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Supports synchronous communication of voice alarm and network management system\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Supports Fast, Gigabit and 10 Gigabit Ethernet fiber connections in SC\/ST\/FC\/LC connectors\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e The main equipment at receiving site have three modes for switching: automatic, forced manual and remote control\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Designed with excellent heat dissipation and temperature adaptability, it can be applied in various complicated environments\u003c\/li\u003e \u003cbr\u003e Front Panel Appearance\u003cbr\u003e \u003c\/ul\u003e \u003cbr\u003e \u003cbr\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e Console: Interface for the serial command line management\u003c\/li\u003e \u003cbr\u003e \u003cli style=\"margin:4px 0;\"\u003e Auto\/Force: Auto\/Forced-mode switch button\u003c\/li\u003e \u003cbr\u003e \u003cli style=\"margin:4px 0;\"\u003e Primary\/Secondary: Click to select the primary or the secondary path under the manual mode.\u003c\/li\u003e \u003cbr\u003e \u003cli style=\"margin:4px 0;\"\u003e Optical interface introduction: There are 8 optical interfaces on the device’s control panel: T1, R1, T2, R2, T3, R3, T4 and R4.\u003c\/li\u003e \u003cbr\u003e Node Protection Card for Packet-Optical Transport Platform\u003cbr\u003e \u003c\/ul\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cbr\u003e In this illustration, the FT-P-OTP800-4S transport platform installed 2 pieces node protection card FT-OBP-C and 1 piece control card. One FT-OBP-C occupies one slot.\u003cbr\u003e \u003cbr\u003e Valid Slots in the Sub-racks\u003cbr\u003e a. In the FT-P-OTP800-2S, valid slots are Slot 1 and Slot 2\u003cbr\u003e b. In the FT-P-OTP800-4S, valid slots are Slot 2 and Slot 4\u003cbr\u003e c. In the FT-P-OTP800-11S, valid slots are Slot 2 and Slot 10\u003cbr\u003e Application Case\u003cbr\u003e \u003cbr\u003e Protection Illustration\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e It shows an example of how you can implement node protection based on 1:1 protection operation. The 1:1 protection adopts 2x2 optical switch technologies. In default mode, the Tx signal towards the main line, through SDH\/ADM node equipment, and the selector chooses the Rx traffic from the main line. When the middle node failure, the network will bypass the failured node and automatically switch to backup line.\u003cbr\u003e \u003cbr\u003e It shows an example of how you can implement node protection based on 1+1 protection operation. In 1+1 operation, a splitter bridge sends the Tx signal to both line (the main line and the backup line) and a 2x1 selector switch selects the signal from one of the line. In default mode, traffic from the main line is selected. In this illustration, SDH\/ADM act as an node between two transmission equipment. When the power failures, the selector near the Rx side of the failed traffic detects the failure, switches over, and selects the traffic from the backup line.\u003cbr\u003e \u003cbr\u003e For more detailed information or any custom requirements, please contact with F-tone sales team at [email protected].\u003c\/p\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cbr\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:458px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003ePerformance\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eParameter\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelengthRange\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1310±50nm \u0026amp; 1550±50nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDynamicRangeofOpticalPower\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-50～+23dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReturnLoss\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≥45dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eInsertion Loss\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;1.5dB (1:1 protected)\u003cbr\u003e 4.5dB (1+1 protected)\u003cbr\u003e \u0026lt;1.5dB (1-1 protected)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOpticalPowerResolution\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.01dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOpticalPowerMeasurementAccuracy\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.5dB (-40~+25dBm)\u003cbr\u003e ≤1.0dB (-50~-40dBm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelengthDependentLoss\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.2dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePolarizationDependentLoss\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤0.1dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSwitchingTime\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤15ms (Typical: 5ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e≤5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-10~50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-20~+75°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e5%~95% no condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDimensions (unit: mm)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e440(W)*220(D)*44.5(H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eManagement Mode\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConsole, Telnet, Network management Button \u0026amp; LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEquipment interface\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e8x Optical Port (LC-UPC by default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eNetworks Capability\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEMS GUI interface\u003cbr\u003e Remote Upgrading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cbr\u003e \u003cbr type=\"_moz\"\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48274830557321,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}]}],"url":"https:\/\/www.fibersoon.com\/collections\/fiber-protection-systems.oembed","provider":"F-tone Networks","version":"1.0","type":"link"}