{"title":"200G QSFP56 QSFP-DD","description":null,"products":[{"product_id":"qsfp56-200g-sr4m-fm","title":"QSFP56-200G-SR4M 200G QSFP56 SR4 PAM4 850nm 100m MTP\/MPO OM3 FEC Fiber Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP56-200G-SR4M-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e 200G QSFP56 SR4 PAM4 Optical Transceiver Module (850nm MTP\/MPO-12 OM3\/OM4 100m with FEC DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e This QSFP56-200G-SR4M supports 200GbE connectivity up to 100-meter transmission distance over multi-mode fiber (MMF) OM4 with four parallel lanes on 850nm center wavelength, operating at 50G per channel. It is compliant with the QSFP56 MSA and IEEE 802.3bs Specification.\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003cbr\u003e \u003c\/h2\u003e \u003cdiv class=\"m_product_description\"\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:506px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eF-tone Part Number\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP56-200G-SR4M\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eVendor Name\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eForm Factor\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP56\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Data Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e212.5Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eWavelength\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Distance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e70m on OM3\/100m on OM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eModulation Format\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eHost Required\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMTP\/MPO-12\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eVoltage Supply\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eCable Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDDM Support\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTransmitter Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850nm VCSEL\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTX Power\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-6.5~+4.0dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Sensitivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; -8.4dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOperation Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMaximum Power\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; 5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eProtocols\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP56 MSA, IEEE 802.3bs\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e200G Ethernet, Data Center Interconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Quality Assurance\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Excellent quality is the foundation of F-tone's survival and development. Our operation team is an expert with many years of experience in the optical communication industry. Our manufacturers are first-class manufacturers in the industry. Many of them have the qualification of OEM for first-class system equipment manufacturers.\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Quality Certification\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e We control the quality of our products, including our strict qualification of manufacturers, quality control process and production technology, and compliance with certification and safety standards. At present, our products meet the industry standards and mainstream quality certification, such as ISO 9001, CE, RoHS, FCC, etc.\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cbr\u003e \u003cbr\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281279234185,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fmq56-0.png?v=1788599792"},{"product_id":"qsfp56-200g-fr4s-fm","title":"QSFP56-200G-FR4S 200G QSFP56 FR4 PAM4 CWDM4 2km LC SMF FEC Fiber Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP56-200G-FR4S-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e 200G QSFP56 FR4 PAM4 CWDM4 lanes MUX\/DEMUX Design 2km Optical Transceiver Module (1271nm 1291nm 1311nm 1331nm LC SMF 2km with FEC DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e This 200GBASE-FR4 optical module supports a 212.5Gb\/s aggregate bit rate with four CWDM lanes MUX\/DEMUX design at the wavelength of 1271nm, 1291nm, 1311nm, 1331nm. It is compliant with the QSFP56 MSA, IEEE 802.3bs, and 200GBASE-FR4. It contains a duplex LC connector for the optical interface and a 38-pin connector for the electrical interface.\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e Product Details\u003cbr\u003e \u003c\/p\u003e \u003cdiv class=\"m_product_description\"\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:506px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eF-tone Part Number\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP56-200G-FR4S\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eVendor Name\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eForm Factor\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP56\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Data Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e212.5Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eWavelength\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1271nm, 1291nm, 1311nm, 1331nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Distance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eModulation Format\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eHost Required\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDuplex LC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eVoltage Supply\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eCable Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDDM Support\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTransmitter Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML CWDM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTX Power\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-4.2~+4.7dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Sensitivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; -8.2dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOperation Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e15 to 65°C (59 to 149 °F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMaximum Power\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; 6.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eProtocols\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP56 MSA, IEEE 802.3bs, 200GBASE-FR4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e200G Ethernet, Data Center Interconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cbr\u003e \u003cbr\u003e Quality Assurance\u003cbr\u003e \u003cbr\u003e Excellent quality is the foundation of F-tone's survival and development. Our operation team is an expert with many years of experience in the optical communication industry. Our manufacturers are first-class manufacturers in the industry. Many of them have the qualification of OEM for first-class system equipment manufacturers.\u003cbr\u003e \u003cbr\u003e \u003cbr\u003e Quality Certification\u003cbr\u003e \u003cbr\u003e We control the quality of our products, including our strict qualification of manufacturers, quality control process and production technology, and compliance with certification and safety standards. At present, our products meet the industry standards and mainstream quality certification, such as ISO 9001, CE, RoHS, FCC, etc.\u003c\/p\u003e \u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281279594633,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fmq56-0_c2ee3937-25f7-4d57-9520-2d7f0addc34f.png?v=1788599813"},{"product_id":"qsfp-dd-200g-lr4-fm","title":"QSFP-DD-200G-LR4 200G QSFP-DD LR4 PAM4 LWDM4 10km LC SMF FEC Optical Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP-DD-200G-LR4-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e 200G QSFP-DD LR4 PAM4 LWDM4 Lanes MUX\/DEMUX Design 10km Optical Transceiver Module (1295.56nm 1300.05nm 1304.58nm 1309.14nm LC SMF 10km with FEC DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e This product supports link lengths of up to 40 kilometers over SMF (single-mode fiber) using a duplex LC connector for 200Gb\/s (PMA4) optical transmission. It is compliant with QSFP-DD MSA and IEEE 802.3bs, whic is for 5G Network, 200G Ethernet, Enterprise Networking application.\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Product Details\u003cbr\u003e \u003c\/p\u003e \u003cdiv class=\"m_product_description\"\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:506px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eF-tone Part Number\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD-200G-LR4\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eVendor Name\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eForm Factor\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Data Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e212.5Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eWavelength\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1295.56nm, 1300.05nm, 1304.58nm, 1309.14nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Distance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e10km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eModulation Format\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eHost Required\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDuplex LC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eVoltage Supply\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eCable Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDDM Support\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTransmitter Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML LWDM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTX Power\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-3.4~+5.3dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Sensitivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; -7.7dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOperation Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMaximum Power\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; 10.8W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eProtocols\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD MSA, IEEE 802.3bs\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e200G Ethernet, Data Center Interconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003cbr\u003e \u003cbr\u003e Quality Assurance\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Excellent quality is the foundation of F-tone's survival and development. Our operation team is an expert with many years of experience in the optical communication industry. Our manufacturers are first-class manufacturers in the industry. Many of them have the qualification of OEM for first-class system equipment manufacturers.\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Quality Certification\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e We control the quality of our products, including our strict qualification of manufacturers, quality control process and production technology, and compliance with certification and safety standards. At present, our products meet the industry standards and mainstream quality certification, such as ISO 9001, CE, RoHS, FCC, etc.\u003c\/p\u003e \u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281279889545,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17123-0.png?v=1788586238"},{"product_id":"qsfp-dd-200g-er4-fm","title":"QSFP-DD-200G-ER4 200G QSFP-DD ER4 PAM4 LWDM4 40km LC SMF FEC Optical Fiber Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP-DD-200G-ER4-FM\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e 200G QSFP-DD ER4 PAM4 4 LAN WDM Lanes MUX\/DEMUX Design 40km Optical Transceiver Module (1295.56nm 1300.05nm 1304.58nm 1309.14nm LC SMF 40km with FEC DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e This QSFP-DD-200G-ER4 is a hot-swapping, QSFP-DD, 200GBASE-ER4 Optical Transceiver Module. It provides up to 40km transmission on single mode fiber (SMF) with FEC using a LC duplex connector. It is compliant with the QSFP-DD MSA and IEEE 802.3bs.\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Product Details\u003cbr\u003e \u003c\/p\u003e \u003cdiv class=\"m_product_description\"\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:491px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eF-tone Part Number\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD-200G-ER4\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eVendor Name\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eForm Factor\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Data Rate\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e212.5Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eWavelength\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1295.56nm, 1300.05nm, 1304.58nm, 1309.14nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMax Distance\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e40km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eModulation Format\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eHost Required\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDuplex LC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eVoltage Supply\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eCable Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDDM Support\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTransmitter Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eEML LWDM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Type\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTX Power\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-0.1~+5.6dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eReceiver Sensitivity\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; -14.1dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOperation Temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMaximum Power\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; 12W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eProtocols\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP-DD MSA, IEEE 802.3bs\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eApplication\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e5G Network, 200G Ethernet, Enterprise Networking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003c\/div\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003cbr\u003e \u003cbr\u003e Quality Assurance\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Excellent quality is the foundation of F-tone's survival and development. Our operation team is an expert with many years of experience in the optical communication industry. Our manufacturers are first-class manufacturers in the industry. Many of them have the qualification of OEM for first-class system equipment manufacturers.\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Quality Certification\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e We control the quality of our products, including our strict qualification of manufacturers, quality control process and production technology, and compliance with certification and safety standards. At present, our products meet the industry standards and mainstream quality certification, such as ISO 9001, CE, RoHS, FCC, etc.\u003c\/p\u003e \u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281280249993,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm17124-0.png?v=1788586230"},{"product_id":"qsfp56-sr4-200g-ma","title":"Mellanox MMA1T00-VS Compatible 200G Ethernet QSFP56 SR4 PAM4 850nm 100m MTP\/MPO APC OM3 FEC Fiber Transceiver","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e QSFP56-SR4-200G-MA\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Mellanox MMA1T00-VS Compatible 200G Ethernet QSFP56 SR4 PAM4 Optical Transceiver Module (850nm MTP\/MPO-12 OM3\/OM4 100m with FEC DDM)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Details\u003c\/h3\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:476px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eMellanox Compatible\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eMMA1T00-VS\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eVendor Name\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eF-tone\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP56\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Data Rate\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e212.5Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax Distance\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e70m on OM3\/100m on OM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eModulation Format\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePAM4\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eHost Required\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMTP\/MPO-12\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eVoltage Supply\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e3.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCable Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMMF\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDDM Support\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850nm VCSEL\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-6.5~+4.0dBm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReceiver Sensitivity\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperation Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e0 to 70～C (32 to 158～F)\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMaximum Power\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt;\u0026gt;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eQSFP56 MSA, IEEE 802.3bs\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e200G Ethernet, Data Center Interconnect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48281451397257,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fmq56-0_c7e072b8-b9b9-445d-9f35-4e5d4004d924.png?v=1788599803"},{"product_id":"generic-compatible-200gbase-sr4-qsfp56-4-x-50g-pam4-850nm-100m-mpo-12-upc-mmf-transceiver-module","title":"Generic Compatible 200GBASE-SR4 QSFP56 4 x 50G PAM4 850nm 100m MPO-12\/UPC MMF Transceiver Module","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003e200GBASE-SR4 QSFP56 Optical Transceiver Module (MMF, 850nm, 100m, MTP\/MPO, DOM)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe QSFP56 Optical Transceiver Module is designed for 200GBASE Ethernet throughput over MTP\/MPO-12 connectors using OM4 multimode fiber (MMF) with a wavelength of 850nm up to 100 meters.\u003cbr\u003eThe transceiver is compliant with IEEE 802.3bs, 200GBASE-SR4, CMIS Rev 4.0 \u0026amp; SFF-8665 standards. Digital diagnostics functions are available via the I2C interface. It is suitable for data centers, high performance computing networks, enterprise core and distribution layer applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eQSFP‑SR4‑200G\u003c\/td\u003e\n\u003ctd\u003eVendor Name\u003c\/td\u003e\n\u003ctd\u003eF-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eQSFP56\u003c\/td\u003e\n\u003ctd\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd\u003e200Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003ctd\u003eMax. Cable Distance\u003c\/td\u003e\n\u003ctd\u003e70m@OM3 \/ 100m@OM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eMPO‑12\/UPC\u003c\/td\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eMMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd\u003eVCSEL 850nm\u003c\/td\u003e\n\u003ctd\u003eReceiver Type\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX Power\u003c\/td\u003e\n\u003ctd\u003e‑3~3dBm\u003c\/td\u003e\n\u003ctd\u003eMinimum Receiver Power\u003c\/td\u003e\n\u003ctd\u003e‑6.5dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Budget\u003c\/td\u003e\n\u003ctd\u003e3.5dBm\u003c\/td\u003e\n\u003ctd\u003eReceiver Overload\u003c\/td\u003e\n\u003ctd\u003e5dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd\u003e4.35W\u003c\/td\u003e\n\u003ctd\u003eExtinction Ratio\u003c\/td\u003e\n\u003ctd\u003e3dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDDM\/DOM\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003ctd\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70℃ (32 to 158℉)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation (Electrical)\u003c\/td\u003e\n\u003ctd\u003e4×50G‑PAM4\u003c\/td\u003e\n\u003ctd\u003eModulation (Optical)\u003c\/td\u003e\n\u003ctd\u003e4×50G‑PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCDR (Clock and Data Recovery)\u003c\/td\u003e\n\u003ctd\u003eTX \u0026amp; RX Built‑in CDR\u003c\/td\u003e\n\u003ctd\u003eFEC Function\u003c\/td\u003e\n\u003ctd\u003eSupport RS‑FEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3bs, QSFP56 MSA, SFF‑8665, CMIS Rev 4.0, RoHS 10\u003c\/td\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin: 10px 0; line-height: 1.8;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48296732950665,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/QSFP-SR4-200G.jpg?v=1788847861"},{"product_id":"generic-compatible-200gbase-fr4-qsfp56-4-x-50g-pam4-1310nm-2km-duplex-lc-smf-transceiver-module","title":"Generic Compatible 200GBASE-FR4 QSFP56 4 x 50G PAM4 1310nm 2km Duplex LC SMF Transceiver Module","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eGeneric Compatible 200GBASE-FR4 QSFP56 Optical Transceiver Module (SMF, 1271nm, 1291nm, 1311nm and 1331nm, 2km, LC, DOM)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe Generic Compatible 200GBASE-FR4 QSFP56 Transceiver Module is designed for 200GBASE Ethernet throughput up to 2km over single-mode fiber (SMF) using a wavelength of 1295nm to 1309nm with duplex LC connectors.\u003cbr\u003eThis transceiver is compliant with IEEE 802.3cd, IEEE 802.3bs, QSFP56 MSA, SFF-8665, SFF-8024, and SFF-8679 standards. The built-in digital diagnostics monitoring (DDM) allows access to real-time operating parameters. It is suitable for 200G Ethernet, Data Center, and Cloud Networks.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eQSFP-FR4-200G\u003c\/td\u003e\n\u003ctd\u003eVendor Name\u003c\/td\u003e\n\u003ctd\u003eF-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003eQSFP56\u003c\/td\u003e\n\u003ctd\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd\u003e200Gbps (4x50Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength\u003c\/td\u003e\n\u003ctd\u003e1271, 1291, 1311 and 1331 nm\u003c\/td\u003e\n\u003ctd\u003eMax. Cable Distance\u003c\/td\u003e\n\u003ctd\u003e2 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003eDuplex LC\/UPC\u003c\/td\u003e\n\u003ctd\u003eMedia\u003c\/td\u003e\n\u003ctd\u003eSMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd\u003eDFB\u003c\/td\u003e\n\u003ctd\u003eReceiver Type\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTX Power\u003c\/td\u003e\n\u003ctd\u003e-4.2~4.7 dBm\u003c\/td\u003e\n\u003ctd\u003eMinimum Receiver Power\u003c\/td\u003e\n\u003ctd\u003e-8.2 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Budget\u003c\/td\u003e\n\u003ctd\u003e4 dB\u003c\/td\u003e\n\u003ctd\u003eReceiver Overload\u003c\/td\u003e\n\u003ctd\u003e4.7 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd\u003e6.5 W\u003c\/td\u003e\n\u003ctd\u003eExtinction Ratio\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;3.5 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDDM\/DOM\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003ctd\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModulation (Electrical)\u003c\/td\u003e\n\u003ctd\u003e4x50G-PAM4\u003c\/td\u003e\n\u003ctd\u003eModulation (Optical)\u003c\/td\u003e\n\u003ctd\u003e4x50G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3cd, IEEE 802.3bs, QSFP56 MSA, SFF-8665, SFF-8024, SFF-8679\u003c\/td\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin: 10px 0; line-height: 1.8;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48296760672393,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/QSFP-FR4-200G.jpg?v=1788848284"},{"product_id":"generic-compatible-200gbase-lr4-qsfp56-4-x-50g-pam4-1310nm-10km-duplex-lc-upc-smf-transceiver-module","title":"Generic Compatible 200GBASE-LR4 QSFP56 4 x 50G PAM4 1310nm 10km Duplex LC\/UPC SMF Transceiver Module","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eGeneric Compatible 200GBASE-LR4 QSFP56 Optical Transceiver Module for Ethernet and Data Center (SMF, 1310nm, 10km, LC, DOM)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eGeneric Compatible QSFP56 transceiver supports up to 10km link lengths over single-mode fiber (SMF) via an LC duplex connector.\u003cbr\u003eThis transceiver is compliant with SFF-8661,and IEEE 802.3bs standards. The built-in digital diagnostics monitoring (DDM) allows access to real-time operating parameters. With these features, this easy to install, hot swappable transceiver is suitable for 200G Ethernet, Data Center, and 5G backhaul.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ctable style=\"width: 99.9369%; height: 391.826px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003cth style=\"width: 20.5363%; height: 19.5913px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 38.2155%; height: 19.5913px;\"\u003eValue\u003c\/th\u003e\n\u003cth style=\"width: 22.6793%; height: 19.5913px;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 17.6791%; height: 19.5913px;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003ctd style=\"width: 20.5363%; height: 19.5913px;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"width: 38.2155%; height: 19.5913px;\"\u003e\u003cspan\u003eQSFP-LR4-200G\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22.6793%; height: 19.5913px;\"\u003eVendor Name\u003c\/td\u003e\n\u003ctd style=\"width: 17.6791%; height: 19.5913px;\"\u003eF-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1826px;\"\u003e\n\u003ctd style=\"width: 20.5363%; height: 39.1826px;\"\u003eForm Factor\u003c\/td\u003e\n\u003ctd style=\"width: 38.2155%; height: 39.1826px;\"\u003eQSFP56\u003c\/td\u003e\n\u003ctd style=\"width: 22.6793%; height: 39.1826px;\"\u003eMax. Data Rate\u003c\/td\u003e\n\u003ctd style=\"width: 17.6791%; height: 39.1826px;\"\u003e200Gbps (4x50Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1826px;\"\u003e\n\u003ctd style=\"width: 20.5363%; height: 39.1826px;\"\u003eWavelength\u003c\/td\u003e\n\u003ctd style=\"width: 38.2155%; height: 39.1826px;\"\u003e\u003cspan\u003e1310nm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22.6793%; height: 39.1826px;\"\u003e\u003cspan\u003eMax Cable Distance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 17.6791%; height: 39.1826px;\"\u003e10km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003ctd style=\"width: 20.5363%; height: 19.5913px;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"width: 38.2155%; height: 19.5913px;\"\u003eDuplex LC\/UPC\u003c\/td\u003e\n\u003ctd style=\"width: 22.6793%; height: 19.5913px;\"\u003eMedia\u003c\/td\u003e\n\u003ctd style=\"width: 17.6791%; height: 19.5913px;\"\u003eSMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003ctd style=\"width: 20.5363%; height: 19.5913px;\"\u003eTransmitter Type\u003c\/td\u003e\n\u003ctd style=\"width: 38.2155%; height: 19.5913px;\"\u003eDFB\u003c\/td\u003e\n\u003ctd style=\"width: 22.6793%; height: 19.5913px;\"\u003eReceiver Type\u003c\/td\u003e\n\u003ctd style=\"width: 17.6791%; height: 19.5913px;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1826px;\"\u003e\n\u003ctd style=\"width: 20.5363%; height: 39.1826px;\"\u003eTX Power\u003c\/td\u003e\n\u003ctd style=\"width: 38.2155%; height: 39.1826px;\"\u003e\u003cspan\u003e-3.4~5.3dBm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 22.6793%; height: 39.1826px;\"\u003eMinimum Receiver Power\u003c\/td\u003e\n\u003ctd style=\"width: 17.6791%; height: 39.1826px;\"\u003e-8.2 dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5913px;\"\u003e\n\u003ctd style=\"width: 20.5363%; height: 19.5913px;\"\u003ePower Budget\u003c\/td\u003e\n\u003ctd style=\"width: 38.2155%; height: 19.5913px;\"\u003e6.3 dB\u003c\/td\u003e\n\u003ctd style=\"width: 22.6793%; height: 19.5913px;\"\u003eReceiver Overload\u003c\/td\u003e\n\u003ctd style=\"width: 17.6791%; height: 19.5913px;\"\u003e\u003cspan\u003e-9.7dBm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1826px;\"\u003e\n\u003ctd style=\"width: 20.5363%; height: 39.1826px;\"\u003eMax. Power Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 38.2155%; height: 39.1826px;\"\u003e8 W\u003c\/td\u003e\n\u003ctd style=\"width: 22.6793%; height: 39.1826px;\"\u003eExtinction Ratio\u003c\/td\u003e\n\u003ctd style=\"width: 17.6791%; height: 39.1826px;\"\u003e\u0026gt;3.5 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1826px;\"\u003e\n\u003ctd style=\"width: 20.5363%; height: 39.1826px;\"\u003eDDM\/DOM\u003c\/td\u003e\n\u003ctd style=\"width: 38.2155%; height: 39.1826px;\"\u003eSupported\u003c\/td\u003e\n\u003ctd style=\"width: 22.6793%; height: 39.1826px;\"\u003eCommercial Temperature Range\u003c\/td\u003e\n\u003ctd style=\"width: 17.6791%; height: 39.1826px;\"\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1826px;\"\u003e\n\u003ctd style=\"width: 20.5363%; height: 39.1826px;\"\u003eModulation (Electrical)\u003c\/td\u003e\n\u003ctd style=\"width: 38.2155%; height: 39.1826px;\"\u003e4x50G-PAM4\u003c\/td\u003e\n\u003ctd style=\"width: 22.6793%; height: 39.1826px;\"\u003eModulation (Optical)\u003c\/td\u003e\n\u003ctd style=\"width: 17.6791%; height: 39.1826px;\"\u003e4x50G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7739px;\"\u003e\n\u003ctd style=\"width: 20.5363%; height: 58.7739px;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"width: 38.2155%; height: 58.7739px;\"\u003eIEEE 802.3cd, IEEE 802.3bs, QSFP56 MSA, SFF-8665, SFF-8024, SFF-8679\u003c\/td\u003e\n\u003ctd style=\"width: 22.6793%; height: 58.7739px;\"\u003eWarranty\u003c\/td\u003e\n\u003ctd style=\"width: 17.6791%; height: 58.7739px;\"\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin: 10px 0; line-height: 1.8;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48301968883849,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/QSFP-LR4-200G.jpg?v=1788931809"},{"product_id":"nvidia-mellanox-compatible-200gbase-sl4-qsfp56-4-x-50g-pam4-850nm-30m-mpo-12-upc-mmf-ethernet-transceiver-module","title":"NVIDIA\/Mellanox Compatible 200GBASE-SL4 QSFP56 4 x 50G PAM4 850nm 30m MPO-12\/UPC MMF Ethernet Transceiver Module","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eNVIDIA\/Mellanox Compatible QSFP56 200G SL4 PAM4 Ethernet Optical Transceiver (MMF, 850nm, 30m, MPO-12\/UPC, DOM)\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe NVIDIA\/Mellanox Compatible QSFP56 Optical Transceiver Module is designed for 200GBASE Ethernet throughput over MTP\/MPO-12 connectors using OM4 multimode fiber (MMF) with a wavelength of 850nm up to 30 meters. It is compliant with IEEE 802.3bs, SFF-8636, and SFF-8665 standards. The module also supports 4x50G breakout applications, enabling flexible migration and interconnection with 50G SFP56-based network architectures. This transceiver is ideal for data centers, high-performance computing (HPC) networks, and enterprise core and distribution layer deployments, delivering high bandwidth, low latency, low power consumption, and scalable network expansion.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\n\u003ctable style=\"width: 99.9369%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8937%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.5367%;\"\u003eQSFP-SL4-200G\u003c\/td\u003e\n\u003ctd style=\"width: 25.7151%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eVendor Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.9648%;\"\u003eF-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8937%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.5367%;\"\u003eQSFP56\u003c\/td\u003e\n\u003ctd style=\"width: 25.7151%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMax. Data Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.9648%;\"\u003e200Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8937%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.5367%;\"\u003e850nm\u003c\/td\u003e\n\u003ctd style=\"width: 25.7151%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMax. Cable Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.9648%;\"\u003e30m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8937%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.5367%;\"\u003eMPO-12\/UPC\u003c\/td\u003e\n\u003ctd style=\"width: 25.7151%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMedia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.9648%;\"\u003eMMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8937%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eTransmitter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.5367%;\"\u003eVCSEL 850nm\u003c\/td\u003e\n\u003ctd style=\"width: 25.7151%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eReceiver Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.9648%;\"\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8937%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eTX Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.5367%;\"\u003e-6.5~4dBm\u003c\/td\u003e\n\u003ctd style=\"width: 25.7151%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMinimum Receiver Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.9648%;\"\u003e-6.5dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8937%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003ePower Budget\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.5367%;\"\u003e3.5dBm\u003c\/td\u003e\n\u003ctd style=\"width: 25.7151%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eReceiver Overload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.9648%;\"\u003e5dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8937%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMax. Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.5367%;\"\u003e4.35W\u003c\/td\u003e\n\u003ctd style=\"width: 25.7151%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eExtinction Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.9648%;\"\u003e3dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8937%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eDDM\/DOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.5367%;\"\u003eSupported\u003c\/td\u003e\n\u003ctd style=\"width: 25.7151%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eCommercial Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.9648%;\"\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8937%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eModulation (Electrical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.5367%;\"\u003e4x50G-PAM4\u003c\/td\u003e\n\u003ctd style=\"width: 25.7151%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eModulation (Optical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.9648%;\"\u003e4x50G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8937%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eCDR (Clock and Data Recovery)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.5367%;\"\u003eTX \u0026amp; RX Built-in CDR\u003c\/td\u003e\n\u003ctd style=\"width: 25.7151%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eInbuilt FEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.9648%;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 25.8937%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 30.5367%;\"\u003eIEEE 802.3bs, QSFP56 MSA, SFF-8665, SFF-8636\u003c\/td\u003e\n\u003ctd style=\"width: 25.7151%;\"\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 16.9648%;\"\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin: 10px 0; line-height: 1.8;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48301993656457,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/QSFP-SL4-200G.jpg?v=1788932706"},{"product_id":"nvidia-mellanox-mma1t00-vs-compatible-200gbase-sr4-qsfp56-4-x-50g-pam4-850nm-100m-mpo-12-upc-mmf-ethernet-transceiver-module","title":"NVIDIA\/Mellanox MMA1T00-VS Compatible 200GBASE-SR4 QSFP56 4 x 50G PAM4 850nm 100m MPO-12\/UPC MMF Ethernet Transceiver Module","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eNVIDIA\/Mellanox MMA1T00-VS Compatible 200GBASE-SR4 QSFP56 Ethernet Optical Transceiver Module (MMF, 850nm, 100m, MTP\/MPO, DOM)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe FS for Mellanox MMA1T00-VS Compatible QSFP56 Optical Transceiver Module is designed for 200GBASE Ethernet throughput over MTP\/MPO-12 connectors using OM4 multimode fiber (MMF) with a wavelength of 850nm up to 100 meters.\u003cbr\u003eThe transceiver is compliant with IEEE 802.3bs, 200GBASE-SR4, SFF-8636 \u0026amp; SFF-8665 standards. It is suitable for data centers, high performance computing networks, enterprise core and distribution layer applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eNVIDIA\/Mellanox Ethernet Compatible\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMMA1T00-VS\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eVendor Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP56\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMax. Data Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200Gbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMax. Cable Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70m@OM3\/100m@OM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/UPC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMedia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eTransmitter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVCSEL 850nm\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eReceiver Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eTX Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-6.5~4dBm\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMinimum Receiver Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-6.5dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003ePower Budget\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5dBm\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eReceiver Overload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMax. Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.35W\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eExtinction Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;3dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eDDM\/DOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eCommercial Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 70°C (32 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eModulation (Electrical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x50G-PAM4\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eModulation (Optical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x50G-PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eCDR (Clock and Data Recovery)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTX \u0026amp; RX Built-in CDR\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eInbuilt FEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3bs, QSFP56 MSA, SFF-8665, SFF-8636\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200G Ethernet, Data centers Interconnect, High performance computing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin: 10px 0; line-height: 1.8;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48302016692361,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/MMA1T00-VS.jpg?v=1788933053"},{"product_id":"nvidia-mellanox-compatible-200gbase-vr2-qsfp56-2-x-100g-pam4-850nm-50m-mpo-12-apc-mmf-transceiver-module","title":"NVIDIA\/Mellanox Compatible 200GBASE-VR2 QSFP56 2 x 100G PAM4 850nm 50m MPO-12\/APC MMF Transceiver Module","description":"\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_title\"\u003e\n\u003ch3 class=\"title\"\u003eNVIDIA\/Mellanox Compatible 200GBASE-VR2 QSFP56 Optical Transceiver Module (MMF, 850nm, 50m, MPO-12\/APC, DOM)\u003c\/h3\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cp\u003eThe NVIDIA\/Mellanox Compatible QSFP56 transceiver supports up to 50m link lengths over multimode fiber (MMF) via MPO-12\/APC connectors. This transceiver is compliant with IEEE 802.3db and IEEE 802.3-2022 Annex 120E standards. The built-in digital diagnostics monitoring (DDM) allows access to real-time operating parameters. Featured with low power, and reliability, it can link upward in spine-leaf architectures for switch-to-switch applications, downward for top-of-rack switch links to Ethernet network adapters. It is the ideal solution for 200G Ethernet, Data Centers and Breakout 2x 200G VR2 Connections.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specification_component\"\u003e\n\u003cdiv class=\"products_specification\"\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"title\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP-VR2-200G\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eVendor Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eF-tone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eForm Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQSFP56\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMax. Data Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e212.5Gbps (2x 106.25Gbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eWavelength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e850nm\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMax. Cable Distance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMPO-12\/APC\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMedia\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMMF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eTransmitter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVCSEL\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eReceiver Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eTX Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-4.6~4dBm\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMinimum Receiver Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-6.3dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003ePower Budget\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.7dB\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eReceiver Overload\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4dBm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eMax. Power Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6.5W\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eExtinction Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;2.5dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eDDM\/DOM\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eCommercial Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25 to 70°C (77 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eModulation (Electrical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4x 50G PAM4\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eModulation (Optical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2x 100G PAM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eCDR (Clock and Data Recovery)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTX \u0026amp; RX Built-in CDR\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eInbuilt FEC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eProtocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEEE 802.3db, IEEE 802.3-2022 Annex 120E, QSFP-DD MSA 6.01, CMIS Rev 4.0\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong class=\"container-nB6Z1e\"\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 20px 0;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp style=\"margin: 10px 0; line-height: 1.8;\"\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp style=\"margin-top: 30px; font-size: 14px; line-height: 1.7; color: #333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48302042644617,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/QSFP-VR2-200G.jpg?v=1788933557"}],"url":"https:\/\/www.fibersoon.com\/fr\/collections\/200g-qsfp56-qsfp-dd.oembed","provider":"F-tone Networks","version":"1.0","type":"link"}