{"title":"OTDR Fiber Launch Box","description":null,"products":[{"product_id":"ft-otdr-fr-x","title":"OTDR Fiber Ring - OTDR Launch \/ Receive Cable","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OTDR-FR-X\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e OTDR Fiber Ring, 30m, 150m, 300m, 500m, 1km for SM, MM, MPO\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Fiber Rings are often a necessity when testing with an OTDR. Fiber Rings are compact launch \/ receive cables designed to measure the insertion loss of the near-end and\/or far-end connection of a fiber optic link using an OTDR. Both a launch and receive cable are required to measure complete link loss of a fiber with an OTDR. A launch cable, which connects the OTDR to the link under test, reveals the insertion loss and reflectance of the near-end connection. A receive cable, which connects to the far-end of the link, reveals the insertion loss and reflectance of the far-end connection.\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cdiv\u003e \u003cstrong style=\"color:#1a1a1a;\"\u003eFeatures\/Benefits\u003c\/strong\u003e \u003cdiv\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e Compact, rugged, lightweight\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e 150, 500, and 1000m lengths standard\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Available with a variety of connector styles\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Compact! Fits easily in OTDR cases or kits\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cstrong style=\"color:#1a1a1a;\"\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e \u003cdiv\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e Use to test link loss with an OTDR\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e For use as OTDR launch cable\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e For use as OTDR receive cable\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Measure insertion loss and reflectance of near- and far-end connections\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cdiv\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cstrong style=\"color:#1a1a1a;\"\u003eOrdering Information\u003c\/strong\u003e\u003c\/p\u003e \u003cdiv\u003e \u003cdiv class=\"wrapper\"\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:420px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003ePART NUMBER\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eDESCRIPTION\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFR-M6-150-x1-x2\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOTDR Fiber Ring OM1 150m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFR-M5-150-x1-x2\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOTDR Fiber Ring OM2 150m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFR-OM3-150-x1-x2\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOTDR Fiber Ring OM3 150m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFR-OM4-150-x1-x2\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOTDR Fiber Ring OM4 150m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFR-SM-150-y1-y2\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOTDR Fiber Ring SM 150m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFR-SM-500-y1-y2\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOTDR Fiber Ring SM 500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFR-SM-1000-y1-y2\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOTDR Fiber Ring SM 1000m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFR-BIF-150-y1-y2\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOTDR Fiber Ring SM (G.657.A2 BIF) 150m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFR-BIF-500-y1-y2\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOTDR Fiber Ring SM (G.657.A2 BIF) 500m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFR-SM-30-MPO-NA-MPO-NA MPO\/APC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOTDR Fiber Ring SM 12F MPO\/APC 30m Type A (non-pinned)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFR-SM-30-MPO-A-MPO-A MPO\/APC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOTDR Fiber Ring SM 12F MPO\/APC 30m Type A (pinned)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFR-SM-61-MPO-PA-MPO-PA-TA MPO\/APC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOTDR Fiber Ring SM 12F MPO\/APC 61m Type A (pinned)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eFR-SM-61-MPO-PA-MPO-PA-TB MPO\/APC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOTDR Fiber Ring SM 12F MPO\/APC 61m Type B (pinned)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cstrong style=\"color:#1a1a1a;\"\u003eNotes:\u003c\/strong\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e a. x1, x2 — connectors for multimode cables, specify type [ST, SC, ASC (angled SC), FC, AFC (angled FC), LC].\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e b. y1, y2 — connectors for single-mode cables, specify type [ST, SC, ASC (angled SC), FC, AFC (angled FC), LC].\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e c. Other fiber types, connector styles, and custom lengths are available by request.\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48256645103753,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm-8823253270665-0.png?v=1788331163"},{"product_id":"otdr-r-500","title":"OTDR Launch Cable Reel w\/ SC,FC,ST,LC connector, 500M","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e OTDR-R-500\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Fiber Optic OTDR Launch Cable Reel, Singlemode, SC\/APC-SC\/APC\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e An OTDR launch cable, which connects the OTDR to the link-under-test, discloses the insertion loss and reflectance of the near-end connection. It is often available on a small spool or within a \"launch box\", which is used to create the proper conditions for testing another similar optical fiber for faults. This method avoids undesirable variations in loss and distance measurements. A launch fiber will help to overcome the blind spot or Dead Zone of an OTDR brought about by high launch power or faults near the launch end of the fiber.\u003c\/p\u003e \u003cdiv class=\"wrapper\"\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:468px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eFiber Type\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e9\/125 Singlemode\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eLength\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e500m\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 1\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 2\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMaterial\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSR Polypropylene\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTypical Loss\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; 0.5dB@1310nM for 1000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOperating temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-40 +55C\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDimension\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e238x141x66mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h3\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Highlights\u003c\/h3\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Fiber Optic OTDR Launch Cable Box\u003c\/p\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e Place the necessary length of fiber between the OTDR and the fiber-under-test\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Help to make a more precise measurement with an OTDR\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Discloses the insertion loss and reflectance of the near-end connection\u003c\/li\u003e \u003c\/ul\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eRobust Metal Retracter\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Make the box easy to carry in actual testment.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eBuilt-in Cable Management\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Helps to reduce cable stress and save space.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eAuto Purge Valve\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Elaborate air vent valve regulates the pressure automatically.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Craftmanship\u003cb\u003e Delicate internal structure\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Non-Metal construction will not dent, corrode, or conduce electricity\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Real Testment\u003cb\u003e Readily carried with compact size and light weight\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Excellent assistant for an OTDR testing in various fiber optic applications\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Extensive Applications\u003cb\u003e Widely used with OTDR to help minimize measurement uncertainty indoor or outdoor\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Test the comprehensive performance of newly installed fiber links and detect problems in the existing fiber links\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cbr\u003e \u003cbr\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48256645169289,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm-8823253336201-0.jpg?v=1788331162"},{"product_id":"ft-otdr-box-sm-1","title":"Fiber Optic OTDR Launch Cable Box, Singlemode 1km SC\/UPC","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OTDR-BOX-SM-1\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Fiber Optic OTDR Launch Cable Box, Singlemode, SC\/UP-SC\/UPC\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e An OTDR launch cable, which connects the OTDR to the link-under-test, discloses the insertion loss and reflectance of the near-end connection. It is often available on a small spool or within a \"launch box\", which is used to create the proper conditions for testing another similar optical fiber for faults. This method avoids undesirable variations in loss and distance measurements. A launch fiber will help to overcome the blind spot or Dead Zone of an OTDR brought about by high launch power or faults near the launch end of the fiber.\u003c\/p\u003e \u003cdiv class=\"wrapper\"\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:468px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eFiber Type\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e9\/125 Singlemode\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eLength\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e1km\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 1\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 2\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMaterial\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSR Polypropylene\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTypical Loss\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; 0.5dB@1310nM for 1000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOperating temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-40 +55C\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDimension\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e238x141x66mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h3\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Highlights\u003c\/h3\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Fiber Optic OTDR Launch Cable Box\u003c\/p\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e Place the necessary length of fiber between the OTDR and the fiber-under-test\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Help to make a more precise measurement with an OTDR\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Discloses the insertion loss and reflectance of the near-end connection\u003c\/li\u003e \u003c\/ul\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eRobust Metal Retracter\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Make the box easy to carry in actual testment.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eBuilt-in Cable Management\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Helps to reduce cable stress and save space.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eAuto Purge Valve\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Elaborate air vent valve regulates the pressure automatically.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Craftmanship\u003cb\u003e Delicate internal structure\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Non-Metal construction will not dent, corrode, or conduce electricity\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Real Testment\u003cb\u003e Readily carried with compact size and light weight\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Excellent assistant for an OTDR testing in various fiber optic applications\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Extensive Applications\u003cb\u003e Widely used with OTDR to help minimize measurement uncertainty indoor or outdoor\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Test the comprehensive performance of newly installed fiber links and detect problems in the existing fiber links\u003c\/p\u003e \u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48256645202057,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm-8823253368969-0.jpg?v=1788331162"},{"product_id":"ft-otdr-sm-05","title":"Singlemode 500m SC\/UPC OTDR Launch Cable Box","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OTDR-SM-05\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Fiber Optic OTDR Launch Cable Box, Singlemode, SC\/UP-SC\/UPC\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e An OTDR launch cable, which connects the OTDR to the link-under-test, discloses the insertion loss and reflectance of the near-end connection. It is often available on a small spool or within a \"launch box\", which is used to create the proper conditions for testing another similar optical fiber for faults. This method avoids undesirable variations in loss and distance measurements. A launch fiber will help to overcome the blind spot or Dead Zone of an OTDR brought about by high launch power or faults near the launch end of the fiber.\u003c\/p\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:468px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eFiber Type\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e9\/125 Singlemode\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eLength\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e500m\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 1\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 2\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMaterial\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSR Polypropylene\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTypical Loss\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; 0.5dB@1310nM for 1000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOperating temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-40 +55C\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDimension\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e238x141x66mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h3\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Highlights\u003c\/h3\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Fiber Optic OTDR Launch Cable Box\u003c\/p\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e Place the necessary length of fiber between the OTDR and the fiber-under-test\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Help to make a more precise measurement with an OTDR\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Discloses the insertion loss and reflectance of the near-end connection\u003c\/li\u003e \u003c\/ul\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e Robust Metal Retracter \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Make the box easy to carry in actual testment.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e Built-in Cable Management \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Helps to reduce cable stress and save space.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e Auto Purge Valve \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Elaborate air vent valve regulates the pressure automatically.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Craftmanship\u003cb\u003e Delicate internal structure\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Non-Metal construction will not dent, corrode, or conduce electricity\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Real Testment\u003cb\u003e Readily carried with compact size and light weight\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Excellent assistant for an OTDR testing in various fiber optic applications\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Extensive Applications\u003cb\u003e Widely used with OTDR to help minimize measurement uncertainty indoor or outdoor\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Test the comprehensive performance of newly installed fiber links and detect problems in the existing fiber links\u003c\/p\u003e \u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48256645955721,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm-8823253532809-0.jpg?v=1788331183"},{"product_id":"ft-otdr-box-sm-01","title":"Fiber Optic OTDR Launch Cable Box, Singlemode 150m SC\/UPC","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OTDR-BOX-SM-01\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Fiber Optic OTDR Launch Cable Box, Singlemode, SC\/UP-SC\/UPC\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e An OTDR launch cable, which connects the OTDR to the link-under-test, discloses the insertion loss and reflectance of the near-end connection. It is often available on a small spool or within a \"launch box\", which is used to create the proper conditions for testing another similar optical fiber for faults. This method avoids undesirable variations in loss and distance measurements. A launch fiber will help to overcome the blind spot or Dead Zone of an OTDR brought about by high launch power or faults near the launch end of the fiber.\u003c\/p\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:468px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eFiber Type\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e9\/125 Singlemode\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eLength\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e150m\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 1\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 2\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMaterial\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSR Polypropylene\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTypical Loss\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; 0.5dB@1310nM for 1000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOperating temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-40 +55C\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDimension\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e238x141x66mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Highlights\u003c\/h3\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Fiber Optic OTDR Launch Cable Box\u003c\/p\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e Place the necessary length of fiber between the OTDR and the fiber-under-test\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Help to make a more precise measurement with an OTDR\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Discloses the insertion loss and reflectance of the near-end connection\u003c\/li\u003e \u003c\/ul\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eRobust Metal Retracter\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Make the box easy to carry in actual testment.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eBuilt-in Cable Management\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Helps to reduce cable stress and save space.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eAuto Purge Valve\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Elaborate air vent valve regulates the pressure automatically.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Craftmanship\u003cb\u003e Delicate internal structure\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Non-Metal construction will not dent, corrode, or conduce electricity\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Real Testment\u003cb\u003e Readily carried with compact size and light weight\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Excellent assistant for an OTDR testing in various fiber optic applications\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Extensive Applications\u003cb\u003e Widely used with OTDR to help minimize measurement uncertainty indoor or outdoor\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Test the comprehensive performance of newly installed fiber links and detect problems in the existing fiber links\u003c\/p\u003e \u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48256646021257,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm-8823253598345-0.jpg?v=1788331185"},{"product_id":"ft-otdr-box-mm-01","title":"Fiber Optic OTDR Launch Cable Box, OM3\/OM4 150m SC\/UPC  LC\/UPC Fiber","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OTDR-BOX-MM-01\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Fiber Optic OTDR Launch Cable Box, Multimode, SC\/UP-LC\/UPC\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e An OTDR launch cable, which connects the OTDR to the link-under-test, discloses the insertion loss and reflectance of the near-end connection. It is often available on a small spool or within a \"launch box\", which is used to create the proper conditions for testing another similar optical fiber for faults. This method avoids undesirable variations in loss and distance measurements. A launch fiber will help to overcome the blind spot or Dead Zone of an OTDR brought about by high launch power or faults near the launch end of the fiber.\u003c\/p\u003e \u003cdiv class=\"wrapper\"\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:468px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eFiber Type\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e50\/125 Multimode\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eLength\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e150m\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 1\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 2\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMaterial\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSR Polypropylene\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTypical Loss\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; 0.5dB@1310nM for 1000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOperating temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-40 +55C\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDimension\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e238x141x66mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h3\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Highlights\u003c\/h3\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Fiber Optic OTDR Launch Cable Box\u003c\/p\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e Place the necessary length of fiber between the OTDR and the fiber-under-test\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Help to make a more precise measurement with an OTDR\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Discloses the insertion loss and reflectance of the near-end connection\u003c\/li\u003e \u003c\/ul\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eRobust Metal Retracter\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Make the box easy to carry in actual testment.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eBuilt-in Cable Management\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Helps to reduce cable stress and save space.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eAuto Purge Valve\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Elaborate air vent valve regulates the pressure automatically.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Craftmanship\u003cb\u003e Delicate internal structure\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Non-Metal construction will not dent, corrode, or conduce electricity\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Real Testment\u003cb\u003e Readily carried with compact size and light weight\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Excellent assistant for an OTDR testing in various fiber optic applications\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Extensive Applications\u003cb\u003e Widely used with OTDR to help minimize measurement uncertainty indoor or outdoor\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Test the comprehensive performance of newly installed fiber links and detect problems in the existing fiber links\u003c\/p\u003e \u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48256646054025,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm-8823253631113-0.jpg?v=1788331186"},{"product_id":"ft-otdr-box-xx","title":"Customized Singlemode Cable OTDR Fiber Launch Box","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OTDR-BOX-XX\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Fiber Optic OTDR Launch Cable Box\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e An \u003cstrong style=\"color:#1a1a1a;\"\u003eOTDR launch cable\u003c\/strong\u003e, which connects the OTDR to the link-under-test, discloses the insertion loss and reflectance of the near-end connection. It \u003cstrong style=\"color:#1a1a1a;\"\u003efiber optic launch cable\u003c\/strong\u003e is often available on a small spool or within a \"launch box\", which is used to create the proper conditions for testing another similar optical fiber for faults. This method avoids undesirable variations in loss and distance measurements. A launch fiber will help to overcome the blind spot or Dead Zone of an OTDR brought about by high launch power or faults near the launch end of the fiber. \u003cstrong style=\"color:#1a1a1a;\"\u003eOTDR Fiber Launch Box\u003c\/strong\u003e\u003c\/p\u003e \u003cdiv class=\"wrapper\"\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:475px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMaterial\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eSR Polypropylene\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTypical Loss\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; 0.5dB@1310nM for 1000 meters\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOperating temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-40 +55C\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDimension\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e305x248x120mm\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h3\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Highlights\u003c\/h3\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Fiber Optic OTDR Launch Cable Box\u003c\/p\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e Place the necessary length of fiber between the OTDR and the fiber-under-test\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Help to make a more precise measurement with an OTDR\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Discloses the insertion loss and reflectance of the near-end connection\u003c\/li\u003e \u003c\/ul\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eRobust Metal Retracter\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Make the box easy to carry in actual testment.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eBuilt-in Cable Management\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Helps to reduce cable stress and save space.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eAuto Purge Valve\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Elaborate air vent valve regulates the pressure automatically.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Craftmanship\u003cb\u003e Delicate internal structure\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Non-Metal construction will not dent, corrode, or conduce electricity\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Real Testment\u003cb\u003e Readily carried with compact size and light weight\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Excellent assistant for an OTDR testing in various fiber optic applications\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Extensive Applications\u003cb\u003e Widely used with OTDR to help minimize measurement uncertainty indoor or outdoor fiber optic launch box.\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Test the comprehensive performance of newly installed fiber links and detect problems in the existing fiber links\u003c\/p\u003e \u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48256646348937,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm-8823253729417-0.jpg?v=1788331191"},{"product_id":"ft-otdr-box-sm-05","title":"Fiber Optic OTDR Launch Cable Box, Singlemode 500m SC\/UPC","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OTDR-BOX-SM-05\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Fiber Optic OTDR Launch Cable Box, Singlemode, SC\/UP-SC\/UPC\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e An OTDR launch cable, which connects the OTDR to the link-under-test, discloses the insertion loss and reflectance of the near-end connection. It is often available on a small spool or within a \"launch box\", which is used to create the proper conditions for testing another similar optical fiber for faults. This method avoids undesirable variations in loss and distance measurements. A launch fiber will help to overcome the blind spot or Dead Zone of an OTDR brought about by high launch power or faults near the launch end of the fiber.\u003c\/p\u003e \u003cdiv class=\"wrapper\"\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:468px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eFiber Type\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e9\/125 Singlemode\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eLength\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e500m\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 1\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 2\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMaterial\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSR Polypropylene\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTypical Loss\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; 0.5dB@1310nM for 1000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOperating temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-40 +55C\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDimension\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e238x141x66mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h3\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Highlights\u003c\/h3\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Fiber Optic OTDR Launch Cable Box\u003c\/p\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e Place the necessary length of fiber between the OTDR and the fiber-under-test\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Help to make a more precise measurement with an OTDR\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Discloses the insertion loss and reflectance of the near-end connection\u003c\/li\u003e \u003c\/ul\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eRobust Metal Retracter\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Make the box easy to carry in actual testment.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eBuilt-in Cable Management\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Helps to reduce cable stress and save space.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eAuto Purge Valve\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Elaborate air vent valve regulates the pressure automatically.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Craftmanship\u003cb\u003e Delicate internal structure\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Non-Metal construction will not dent, corrode, or conduce electricity\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Real Testment\u003cb\u003e Readily carried with compact size and light weight\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Excellent assistant for an OTDR testing in various fiber optic applications\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Extensive Applications\u003cb\u003e Widely used with OTDR to help minimize measurement uncertainty indoor or outdoor\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Test the comprehensive performance of newly installed fiber links and detect problems in the existing fiber links\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003cbr\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48278856269961,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm16177-0.jpg?v=1788528037"},{"product_id":"ft-otdr-box-sm-2","title":"Fiber Optic OTDR Launch Cable Box, Singlemode 2km SC\/UPC","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OTDR-BOX-SM-2\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Fiber Optic OTDR Launch Cable Box, Singlemode, SC\/UP-SC\/UPC\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e An OTDR launch cable, which connects the OTDR to the link-under-test, discloses the insertion loss and reflectance of the near-end connection. It is often available on a small spool or within a \"launch box\", which is used to create the proper conditions for testing another similar optical fiber for faults. This method avoids undesirable variations in loss and distance measurements. A launch fiber will help to overcome the blind spot or Dead Zone of an OTDR brought about by high launch power or faults near the launch end of the fiber.\u003c\/p\u003e \u003cdiv class=\"wrapper\"\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:468px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eFiber Type\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e9\/125 Singlemode\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eLength\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e2km\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 1\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 2\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMaterial\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSR Polypropylene\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTypical Loss\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; 0.5dB@1310nM for 1000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOperating temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-40 +55C\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDimension\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e238x141x66mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h3\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Highlights\u003c\/h3\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Fiber Optic OTDR Launch Cable Box\u003c\/p\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e Place the necessary length of fiber between the OTDR and the fiber-under-test\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Help to make a more precise measurement with an OTDR\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Discloses the insertion loss and reflectance of the near-end connection\u003c\/li\u003e \u003c\/ul\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eRobust Metal Retracter\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Make the box easy to carry in actual testment.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eBuilt-in Cable Management\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Helps to reduce cable stress and save space.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eAuto Purge Valve\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Elaborate air vent valve regulates the pressure automatically.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Craftmanship\u003cb\u003e Delicate internal structure\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Non-Metal construction will not dent, corrode, or conduce electricity\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Real Testment\u003cb\u003e Readily carried with compact size and light weight\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Excellent assistant for an OTDR testing in various fiber optic applications\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Extensive Applications\u003cb\u003e Widely used with OTDR to help minimize measurement uncertainty indoor or outdoor\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Test the comprehensive performance of newly installed fiber links and detect problems in the existing fiber links\u003c\/p\u003e \u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48278856630409,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm16179-0.jpg?v=1788528048"},{"product_id":"ft-otdr-box-sm-10","title":"Fiber Optic OTDR Launch Cable Box, Singlemode 10km SC\/UPC","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e FT-OTDR-BOX-SM-10\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Fiber Optic OTDR Launch Cable Box, Singlemode, SC\/UP-SC\/UPC\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e An \u003cstrong style=\"color:#1a1a1a;\"\u003eOTDR launch cable\u003c\/strong\u003e, \u003cstrong style=\"color:#1a1a1a;\"\u003efiber optic launch box\u003c\/strong\u003e, which connects the OTDR to the link-under-test, discloses the insertion loss and reflectance of the near-end connection. It is often available on a small spool or within a \"launch box\", which is used to create the proper conditions for testing another similar optical fiber for faults. This method avoids undesirable variations in loss and distance measurements. A launch fiber will help to overcome the blind spot or Dead Zone of an OTDR brought about by high launch power or faults near the launch end of the fiber.\u003c\/p\u003e \u003cdiv class=\"wrapper\"\u003e\u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:468px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eFiber Type\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e9\/125 Singlemode\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eLength\u003c\/b\u003e\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003e10km\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 1\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eConnector 2\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSC\/UPC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eMaterial\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eSR Polypropylene\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eTypical Loss\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u0026lt; 0.5dB@1310nM for 1000 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eOperating temperature\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-40 +55C\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e\u003cb\u003eDimension\u003c\/b\u003e\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e238x141x66mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e \u003c\/h3\u003e \u003ch3 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Product Highlights\u003c\/h3\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Fiber Optic OTDR Launch Cable Box\u003c\/p\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e Place the necessary length of fiber between the OTDR and the fiber-under-test\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Help to make a more precise measurement with an OTDR\u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e Discloses the insertion loss and reflectance of the near-end connection\u003c\/li\u003e \u003c\/ul\u003e \u003cul style=\"margin:10px 0 10px 22px;line-height:1.9;\"\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eRobust Metal Retracter\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Make the box easy to carry in actual testment.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eBuilt-in Cable Management\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Helps to reduce cable stress and save space.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003cli style=\"margin:4px 0;\"\u003e \u003cdl\u003e \u003cdt\u003e \u003c\/dt\u003e \u003cdd\u003e \u003cspan\u003eAuto Purge Valve\u003c\/span\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Elaborate air vent valve regulates the pressure automatically.\u003c\/p\u003e \u003c\/dd\u003e \u003c\/dl\u003e \u003c\/li\u003e \u003c\/ul\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Craftmanship\u003cb\u003e Delicate internal structure\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Non-Metal construction will not dent, corrode, or conduce electricity\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e On the Importance of Real Testment\u003cb\u003e Readily carried with compact size and light weight\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Excellent assistant for an OTDR testing in various fiber optic applications\u003c\/p\u003e \u003chr\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Extensive Applications\u003cb\u003e Widely used with OTDR to help minimize measurement uncertainty indoor or outdoor\u003c\/b\u003e\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Test the comprehensive performance of newly installed fiber links and detect problems in the existing fiber links\u003c\/p\u003e \u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48278856958089,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm16183-0.jpg?v=1788528057"}],"url":"https:\/\/www.fibersoon.com\/fr\/collections\/otdr-fiber-launch-box.oembed","provider":"F-tone Networks","version":"1.0","type":"link"}