{"product_id":"1480nm-polarization-maintaining-faraday-rotator-mirror","title":"1480nm Polarization Maintaining Faraday Rotator Mirror","description":"\u003cp style=\"font-size:15px;line-height:1.8;margin:0 0 16px;\"\u003eThe Polarization Maintaining Faraday Mirror is manufactured mainly for sensing system, such as FOCT, Hydrophone, Gyro. The Faraday Mirro has such charateristics: compact size, high extinction ratio, high stability, etc.\u003c\/p\u003e\u003ch3 style=\"font-size:18px;margin:20px 0 10px;\"\u003eFeatures \u0026amp; Applications\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:14px 0 24px;font-size:14px;line-height:1.5;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;padding:10px 14px;border:1px solid #d0d0d0;text-align:left;font-weight:bold;\"\u003eFeatures\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;padding:10px 14px;border:1px solid #d0d0d0;text-align:left;font-weight:bold;\"\u003eApplications\u003c\/th\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003eLow Insertion Loss\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003eFiber Optic Instruments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003eHigh Return Loss\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003eFiber Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003eHigh Reliability\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003eFiber Lasers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003eHigh Stability\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003eCoherent Detecting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3 style=\"font-size:18px;margin:20px 0 10px;\"\u003eSpecifications\u003c\/h3\u003e\u003ctable style=\"width:100%;border-collapse:collapse;margin:14px 0 24px;font-size:14px;line-height:1.5;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;padding:10px 14px;border:1px solid #d0d0d0;text-align:left;font-weight:bold;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;padding:10px 14px;border:1px solid #d0d0d0;text-align:left;font-weight:bold;\"\u003eUnit\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;padding:10px 14px;border:1px solid #d0d0d0;text-align:left;font-weight:bold;\"\u003eValue\u003c\/th\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003eCenter Wavelength\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003enm\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003e1480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003eOperating Wavelength Width\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003enm\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003e±15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003eFaraday Rotation Angle for CWL\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003edeg\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003e45 \/ 90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003eMax. Insertion Loss at 23 ℃\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003edB\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003e0.6 \/ 0.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003eMin. Extinction Ratio at 23 ℃\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003edB\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003eMax. Rotation Angle Tolerance for CWL\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003edeg\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003e±3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003eMax. Polarization Mode Dispersion\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003eps\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003e0.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003eMax. Power Handling (CW)\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003emW\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003eMax. Tensile Load\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003eN\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003eAxis Alignment\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003e-\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003eBoth axis working\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003eFiber Type\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003e-\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003ePM Panda Fiber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003e℃\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#ffffff;\"\u003e-5~+70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003e℃\u003c\/td\u003e\n\u003ctd style=\"padding:9px 14px;border:1px solid #e0e0e0;background:#f5f5f5;\"\u003e-40~+85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3 style=\"font-size:18px;margin:20px 0 10px;\"\u003eOrdering Information\u003c\/h3\u003e\u003cdiv style=\"font-size:14px;line-height:1.7;\"\u003e  PMFM-①①①①-②-③③③-④⑤-⑥-⑦\u003cbr\u003e①①①①\u003cbr\u003e- Wavelength:\u003cbr\u003e 1480=1480nm, SSSS=Specified\u003cbr\u003e②\u003cbr\u003e- Rotating Angle:\u003cbr\u003e 1=45°, 2=90°\u003cbr\u003e③③③\u003cbr\u003e- Fiber Type: \u003cbr\u003e 001=PM1550, SSS=Specified\u003cbr\u003e④\u003cbr\u003e- \u003c\/div\u003e\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. rther details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":47980560154761,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/1480nm_Polarization_Maintaining_Faraday_Rotator_Mirror_01.jpg?v=1787309035","url":"https:\/\/www.fibersoon.com\/products\/1480nm-polarization-maintaining-faraday-rotator-mirror","provider":"F-tone Networks","version":"1.0","type":"link"}