{"product_id":"mc-lce-st-om2-2m","title":"2m LC to ST OM2 Mode Conditioning Fiber Optic Patch Cable","description":"\u003cp style=\"margin:0 0 14px;line-height:1.8;\"\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e MC-LCE-ST-OM2-2M\u003c\/p\u003e\n\u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e LC Equip to ST Multimode OM2 50\/125 Mode Conditioning Patch Cable\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e F-tone manufactures and supplies standard and custom length 50\/125,62.5\/125 and OEM equivalent mode conditioning fiber optic patch cords for 1000BASE-LX\/LH Gigabit Ethernet(1300nm long wavelength)applications installed into existing multimode cable plants. These specialized cords help avoid Differential Mode Delay(DMD)effects that can occur when long wave transceiver modules operate at both single-mode and multimode wavelengths. And they are available with FC,ST,SC,LC and MT-RJ connectors.\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e How the Mode Conditioning Cable Works\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e The need for this conditioning fiber optic patch cord is due to the single-mode launch nature of the-LX or long-wave(1300nm)transceiver modules used for Gigabit Ethernet. Launching a single-mode laser into the center of a multimode fiber can cause multiple signals to be generated that confuse the receiver at the other end of the fiber. In that case,a mode conditioning patch cord eliminates these multiple signals by allowing the single-mode launch to be offset away from the center of a multimode fiber. This offset point creates a launch that is similar to typical multimode LED launches.(see diagram below)\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Features and Application of F-tone's MCP (Mode Conditioning Patch Cable)\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e With following excellent characteristics, mode conditioning patch cables can be used to deploy new high-speed 1000BASE-LX routers, switches, or transceivers within existing multimode system backbones. These cables can be applied in Local Area Networks and Metropolitan Area Systems.\u003c\/p\u003e \u003cbr\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"display:flex;flex-wrap:wrap;gap:16px;margin:14px 0;\"\u003e\u003cdiv style=\"flex:1 1 260px;min-width:240px;padding:14px 18px;background:#fbfcfd;border:1px solid #e6edf3;border-radius:8px;line-height:1.85;\"\u003eIncreased transmission bandwidth up to 4 timesFits existing cabling schemeEasy installation,Removes effects form DMDPermanent, low-profile offset closurePC, UPC, APC polish typesLow insertion lossReduced modal noiseOFNR rated jacket complies with strict building codesCompliant with IEEE 802.3 applications\u003c\/div\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e How to Install the Mode Conditioning Cable\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e If your gigabit LX switch is equipped with SC or LC connectors, please be sure to connect the yellow leg (Singlemode) of the cable to the transmit side, and the orange leg (multimode) to the receive side of the equipment. It is imperative that this configuration be maintained on both ends. The swap of transmit and receive can only be done at the cable plant side. (see diagram below)\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Notes\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e 1. In some cases, customers might experience that a link would be operating properly over FDDI-grade, OM1 or OM2 fiber types without MCP. However please note there is no guarantee link will be operating properly over time, and the recommendation remains to use the MCP.\u003cbr\u003e 2. There is a risk associated to this type of nonstandard deployment without MCP, especially when the jumper cable is an FDDI-grade or OM1 type. In such case the power coupled directly into a 62.5-micron fiber could be as high as a few dBm and the adjacent receiver will be saturated. This can cause high bit error rate, link flaps, link down status and eventually irreversible damaged to the device.\u003cbr\u003e 3. Mode conditioning patch cords can only convert single-mode to multimode. If you want to convert multimode to single-mode, then a media converter will be required.\u003cbr\u003e 4. Another alternative for short reaches within the same location is to use a single-mode patch cable. There will be no saturation over single-mode fiber.\u003cbr\u003e \u003cbr\u003e Specifications of Mode Conditioning Patch Cable (Notes:A B C and D,corresponding to A B C and D on Fig.2).\u003c\/p\u003e \u003cdiv class=\"wrapper\"\u003e \u003cdiv style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:20px 0;\"\u003e\u003ctable style=\"width:100%;min-width:421px;border-collapse:collapse;font-size:14px;line-height:1.55;color:#333;background:#fff;border:1px solid #d8e2ec;table-layout:auto;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background:#30A8E4;\"\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eTransmission Direction\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eTesting Wavelength\u003c\/th\u003e\n\u003cth style=\"background:#30A8E4;color:#ffffff;font-weight:600;padding:11px 14px;text-align:left;border:1px solid #2b95cb;vertical-align:middle;overflow-wrap:break-word;word-break:break-word;\"\u003eInsertion Loss\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDuB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850nm-1300nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax 0.30dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eBuD\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850nm-1300nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax 0.30dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCuA\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850nm-1300nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e15.0dB(50\/125um) 18.0dB(62.5\/125um)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eAuC\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e850nm-1300nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eMax 0.30dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eCuA\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1310nm-1550nm\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e2.10dB(50\/125um) 2.60dB(62.5\/125um)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eReturn Loss\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eAPC 60.0dB UPC 50.0dB\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e35.0dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f5f5f5;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eDurability\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e1000 mating\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003etypical0.20dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#ffffff;\"\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-40 to 85C\u003c\/td\u003e\n\u003ctd style=\"padding:10px 14px;border:1px solid #d8e2ec;vertical-align:top;overflow-wrap:break-word;word-break:break-word;\"\u003e-40 to 185F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e \u003c\/div\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Things to Know When Using Mode Conditioning Cables\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e Mode conditioning patch cords are usually used in pairs. Which means that you will need a mode conditioning patch cord at each end to connect the equipment to the cable plant.\u003cbr\u003e Generally, Mode Conditioning patch cords are required for link distances greater than 984 feet (300 meters).\u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003ch2 style=\"margin:18px 0 10px;font-size:17px;color:#1a1a1a;\"\u003e Detailed Picture(Offset)\u003c\/h2\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e \u003cp style=\"margin:10px 0;line-height:1.8;\"\u003e \u003c\/p\u003e\u003cbr\u003e\t \n\u003cp style=\"margin-top:30px;font-size:14px;line-height:1.7;color:#333;\"\u003e\u003cstrong\u003eThis product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!\u003c\/strong\u003e\u003cbr\u003eImportant Notice:\u003cbr\u003ePerformance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.\u003cbr\u003eThe publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.\u003c\/p\u003e","brand":"F-tone Networks","offers":[{"title":"Default Title","offer_id":48277697921161,"sku":null,"price":0.0,"currency_code":"CNY","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0665\/8011\/9689\/files\/fm14043-0.jpg?v=1788514483","url":"https:\/\/www.fibersoon.com\/products\/mc-lce-st-om2-2m","provider":"F-tone Networks","version":"1.0","type":"link"}