Corning Fiber OM1 Multimode Duplex Zipcord Tight Buffer Riser Indoor Fiber Optic Cable

Corning Fiber OM1 Multimode Duplex Zipcord Tight Buffer Riser Indoor Fiber Optic Cable

Afficher tous les détails

Part Number: DZC-A1bCR

Riser Indoor Duplex Zipcord Tight Buffer Fiber Optic Cable, Corning OM1 Multimode Fiber

The duplex zipcord tight buffer cable is easily split into two single core cable, suitable for patch cord making. And this a kind of indoor cable, could be used in the interconnection of fiber optic equipment.

This duplex cable consist of two child single core fiber. Each single fiber is coated with 250µm soft plastic, and then covered with a 900µm tight buffer thick layer of hard plastic, which add some fiber protection. The Kevlar yarn material ensure a good performance of tensile strenghth. And the Flame retardant outer jacket could be used in Riser enviroment. The cable diameter of each child single-fiber is 1.6mm, 2.0mm, 3.0mm optional.

Item Details

  • Fiber Count: 2 Fibers

  • Fiber Type: 62.5/125μm Multimode Corning Fiber

  • Out Jacket: Riser

  • Cable DIA.: 1.6mm, 2.0mm, 3.0mm Optional

  • Fiber Color: Orange

Cable Structure

Features
  • Soft, flexible and easy to do stripping, splicing and cabling
  • Easily split into two single core cable
  • Good mechanical and environmental characteristics
  • The mechanical and physical characteristics of the outer jacket meet the requirement of relevant standards
  • Kevlar yarn material ensure a good performance of tensile strength
  • 900µm tight buffer protect the fiber well
Application
  • Used in patch cords and pigtails
  • Interconnection of fiber optic equipment

Package

Package 1
Package 2
Package 1: usually for indoor cable, light weight cables.
Package 2: usually for outdoor cable, heavy weight cables
Usually for each roll, the cable length is 2km, but we could provide customized package for different cable lengths.

Mark


Usually we only attach Test Report on the out package of the cable, but we could also mark as your requirements, such as:
1. Company Name
2. Cross /Net weight
3. Drum No: XX
4. Cable Length : XX

Cable production throughout the chart



Tight buffer Diameter Out Sheath
Diameter
Weight Minimum Allowable Tensile Strength
(N)
Minimum Allowable Crush Load
(N/100mm)
Minimum Bending Radius
(MM)
Storage
Temperature
(MM) (MM) (KG) short term long term short term long term short term long term (℃)
0.6 1.6x3.4 6 150 80 500 100 20D 10D -20+60
0.6 1.8x3.8 7 150 80 500 100 20D 10D -20+60
0.9 2.0x4.2 9 150 80 500 100 20D 10D -20+60
0.9 2.4x5.0 11 150 80 500 100 20D 10D -20+60
0.9 2.8x5.8 13 150 80 500 100 20D 10D -20+60
0.9 3.0x6.2 15 150 80 500 100 20D 10D -20+60


G.652 50/125µm 62.5/125µm
Attenuation
(+20°C) (dB/km)
@850nm ≤3.0 ≤3.0
@1300nm ≤1.0 ≤1.0
@1310nm ≤0.36
@1550nm ≤0.22
Bandwidth (Class A) (MHz·km) @850nm ≥600 ≥200
@1300nm ≥1200 ≥600
Numerical Aperture 0.200±0.015NA 0.275±0.015NA
Cable Cut-off Wavelength λcc (nm) ≤1260



This product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!
Important Notice:
Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.
The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.

Power and Wavelength Testing

Test the signal delivering strength and wavelength, to ensure the signal decoding capacity of the receiver, and the wavelength remains consistent from the transmitter to the receiver.

Power and Wavelength Testing

Traffic Testing

Test the bit error rate and packet loss rate, to make them meet the corresponding standards and ensure the performance of transceivers.

Traffic Testing

Optical Performance Testing

Test the transceivers' eye diagram situation, receiving sensitivity, extinction ratio, wavelength, light-emitting, light-receiving, current and voltage, to ensure the signal quality, stability and reliability of the transmission.

Optical Performance Testing

End Face Testing

Check the end face of the transceivers and keep them clean for more stable data transmission, better performance, and durability.

End Face Testing

Various Switch Tests

Every module is quality tested for compatibility in the multi-brand switches environment, guaranteeing flawless operations.

Various Switch Tests

About F-tone Networks

F-tone Networks is now a world leader in development of optical transceivers and provide a wide range of high-speed optical solutions for optical communication networking, especially for AI, Data Center, enterprise data networking, Industry, aerospace, mining, shipbuilding, railway, metro, long haul transport networking, and mobile access networking applications
F-tone Networks invested in foundational photonics technologies and extensive product development and engineering with global presence in many area also.