EOC - Ethernet over Coax Master Side Unit

EOC - Ethernet over Coax Master Side Unit

Просмотреть всю информацию

Part Number: EOC-M-

Ethernet over Coax Master Side Unit - EOC

EOC solutions for broadcast and TV can make a full use of current network coaxial cable, which can decrease the cost of net-building. And the solution has advantages of easy construction, less operation and fast reconstruction. The noise in coaxial network cannot influence the system transmission quality. Low cost of terminal equipment can decrease the investment of customers.

The EOC head is high bandwidth bridge equipment from Ethernet to coaxial network. It takes charge in modulating the Slave terminal equipment (EOC series) linked with it. It is often located in the position of AMP or receiver in district. Single Master can link with 10 to 253 terminal slaves, and the concurrency can reach 128 customers. The system can adapt to Chinese current HFC, and coexist with CATV, DVB digital TV.

Functional Features

  • TV and bidirectional data can be transmitted over one coaxial cable at the same time, so it simplifies the bidirectional reconstruction of HFC network
  • Uses current broadcast and TV HFC network to provide the customers with digital TV, interactive TV and broadband service
  • Easy construction, plug-and-play, fast deployment, no need for repaving cable and interrupting persons
  • Bidirectional maximum bandwidth can be 100M; the ability of anti-noise is much higher than Cable Modem; can operate under the abominable network environment
  • Small volume, low weight, adapts to family, corridor and district construction
  • Safe and reliable, stable operation, economy and practical
  • TV port can be compliant with all the mainstream CATV equipment such as splitter, TV set and optical emitter, etc.
  • Data port can be compliant with all the Ethernet equipment such as switch, router, IP set-top box, PC and etc.
  • Embedded system, which can set all the management configuration, such as setting IP and password, through HTTP landing

Specification

System Parameter Technical Index
Standard Ethernet Standard IEEE 802.3, IEEE802.3x, IEEE802.3u
Protocol CSMA/CA, TDMA(In the Future)
Transmission Rate 200Mbps
Modulation Technology OFDM anti-noise modulation, 1024/256/128/64 QAM, DQPSK,DQPSK ROBO
Number of Customers 253 Slave terminal
MAX RF Attenuation Distance <500m(<60dB attenuation)
Frequency Range 5~35MHz
Emitting Power ≥ -50dBm
Safety 128-bit AES data encryption
QoS IEEE 802.1 Q (VLAN tagging);ToS (Type of Service);MAC Address Routing
Requirement/td> Operating Temperature: -10℃ ~ 60℃
Storage Temperature: -40℃ ~ 80℃
Relative Humidity: 5% ~ 95% (noncondensing)
and EMC Follows the standard of FCC,UL,CE,TUV,CSA
Power Supply(standard) 60V/AC(feeding);220V/AC(mains)(optional)
Consumption ≤ 10W




This product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!
Important Notice:
Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.
The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.

Power and Wavelength Testing

Test the signal delivering strength and wavelength, to ensure the signal decoding capacity of the receiver, and the wavelength remains consistent from the transmitter to the receiver.

Power and Wavelength Testing

Traffic Testing

Test the bit error rate and packet loss rate, to make them meet the corresponding standards and ensure the performance of transceivers.

Traffic Testing

Optical Performance Testing

Test the transceivers' eye diagram situation, receiving sensitivity, extinction ratio, wavelength, light-emitting, light-receiving, current and voltage, to ensure the signal quality, stability and reliability of the transmission.

Optical Performance Testing

End Face Testing

Check the end face of the transceivers and keep them clean for more stable data transmission, better performance, and durability.

End Face Testing

Various Switch Tests

Every module is quality tested for compatibility in the multi-brand switches environment, guaranteeing flawless operations.

Various Switch Tests

About F-tone Networks

F-tone Networks is now a world leader in development of optical transceivers and provide a wide range of high-speed optical solutions for optical communication networking, especially for AI, Data Center, enterprise data networking, Industry, aerospace, mining, shipbuilding, railway, metro, long haul transport networking, and mobile access networking applications
F-tone Networks invested in foundational photonics technologies and extensive product development and engineering with global presence in many area also.