Part Number: UTP-CAT3-FT003
305m 100 Pairs Cat3 Unshielded Twisted Pair (UTP) Bulk Cable
Unshielded Copper cable, 2/25/50/100 pairs, category 3, solid
Cable is used for indoor installation
Specifications:
- Meets EIA/TIA 568-B for category 3 requirements
- Fire protection – IEC60332-1 (CM)
- The cable meets IEC 60332-1 fire safety standard
Applications
- Voice
- 10BaseT
- 100BaseVG
- AnyLAN
- 4Mbps Token Ring
- 10Mbps Ethernet
- 55Mps ATM
- ISDN
Materials:
- Conductive material: soft annealed electrolytic copper
- Conductor insulation: HDPE
- The cable jacket: PVC
Technical characteristics:
- Conductor diameter: 0.5 mm (0.019") (24 AWG)
- Insulated conductor diameter: 0.9 mm (0.035")
- Outer cable diameter: 200 mm (0.78")
- Jacket thickness: 1.0 mm (0.039")
- Maximum strand pitch: 150 mm (5.9")
- Minimum bend radius: 8 outer cable diameters
- Conductor elongation: 14% minimum
- Operating temperature: -10°C – +50°C (+14°F – +122°F)
- Weight per 1000 ft (304.8 m): 169.2 kg (372.9 lbs)
- Standard package: 500 m (1640 ft)
Electrical characteristics:
| Max DC Resistance at 20°C (68°F) | 9.38 Ohm/100 m (2.9 Ohm/100 ft) |
|---|---|
| Max Resistance Unbalance | 3% |
| Max Capacitance unbalance – pair-to-ground at 1kHz | 330 pF/100 m (101 pF/100 ft) |
| Characteristic Impedance at 1-16 MHz | 85-115 Ohm |
| Min worst pair Structural Return Loss (SRL) Up to 10 MHz At 16 MHz |
12 dB 10 dB |
| Max attenuation at 20°C (68°F) and At 772 kHz At 1 MHz At 4 MHz At 8 MHz At 10 MHz At 16 MHz |
2.2 dB/100 m (0.67 dB/100 ft) 2.6 dB/100 m (0.79 dB/100 ft) 5.6 dB/100 m (1.70 dB/100 ft) 8.5 dB/100 m (2.59 dB/100 ft) 9.7 dB/100 m (2.96 dB/100 ft) 13.1 dB/100 m (3.99 dB/100 ft) |
| Min worst pair to pair NEXT loss at 772 kHz At 772 kHz At 1 MHz At 4 MHz At 8 MHz At 10 MHz At 16 MHz |
43 dB 41 dB 32 dB 27 dB 26 dB 23 dB |
| Min Relative Velocity of Propagation at 10 MHz | 0,585 |
This product belongs to F-tone Networks' optical components product line. For detailed specifications, please contact our sales team. Thank you!
Important Notice:
Performance figures, data and any illustrative material provided in this data sheet are typical and must be specifically confirmed in writing by F-tone Networks before they become applicable to any particular order or contract. In accordance with the F-tone Networks policy of continuous improvement specifications may change without notice.
The publication of information in this data sheet does not imply freedom from patent or other protective rights of F-tone Networks or others. Further details are available from any F-tone Networks sales representative.